It is important to provide a regular unidirectional air distribution in an operating room to reduce the number of particles. Measurements were taken in the one of the operating rooms at Uludag University Medical School, with laminar air flow unit and two-cornered outlet which was thought to have some airflow problems. Moreover, a three-dimensional computational fluid dynamics model has been developed where the measurements were taken in. The distributions of air velocity, temperature, and relative humidity have been examined and compared with the measurements to validate the computational fluid dynamics analyses. In addition to present model, four-cornered outlet operating room has been analyzed and compared with the results of two-cornered one. It is concluded that the case of four-cornered outlet provides more suitable thermal distribution, which results in a reduction of the particle numbers in the interior. Although there is no significant change in temperature and relative humidity in the operating room, air distribution changes dramatically.
Abstract:In this study, thermal insulation thickness used in the outer walls of buildings composing of different insulation applications having the same thermal resistance was optimized by considering condensation. The minimum insulation thickness required to prevent condensation (i.e. optimum insulation thickness) in building structural component was determined. Heat and mass transfer calculations within the structural component were performed with respect to various indoor-outdoor temperature and relative humidity values and results were given in graphs. It was observed that optimum insulation thickness is generally increased with an increase in the indoor temperature, indoor relative humidity and outdoor relative humidity. It was concluded that type of insulation application does not significantly affect optimum insulation thickness at low and medium level (θi<0.60) indoor relative humidity conditions. It was also observed that externally insulated wall application generally yields better results at high indoor and outdoor relative humidity conditions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.