Investigation on the Influence of Refrigerant Charge Amount on the Cooling Performance of Air Conditioning Heat Pump System for Electric Vehicles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
3
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 20 publications
(4 citation statements)
references
References 14 publications
0
3
0
Order By: Relevance
“…So far, no research publications have been found that discuss the effect of system evacuation duration on AC performance. Instead of system evacuation, the studies of the effect of refrigerant charge have been conducted for decades [6][7][8][9]. In textbooks on refrigeration and air conditioning, it is only explained that an evacuation system up to a certain vacuum level is important to ensure the refrigeration system works well.…”
Section: Introductionmentioning
confidence: 99%
“…So far, no research publications have been found that discuss the effect of system evacuation duration on AC performance. Instead of system evacuation, the studies of the effect of refrigerant charge have been conducted for decades [6][7][8][9]. In textbooks on refrigeration and air conditioning, it is only explained that an evacuation system up to a certain vacuum level is important to ensure the refrigeration system works well.…”
Section: Introductionmentioning
confidence: 99%
“…Either excessive charge or insufficient charge could lead to a decrease of the system heating and cooling performance [20,21]. With an increment of refrigerant charged into system, the superheat decreases and subcooling increases constantly.…”
Section: Introductionmentioning
confidence: 99%
“…After the intersection, the subcooling line would have a short plateau before increase again, and the optimum charge of the system could be determined. For a SL‐ACHP system, the charge determination experiment was conducted by each method introduced in the previous work . The experimental results under cooling mode showed the intersection of subcooling and superheat curves, which was used to determine the critical charge accurately.…”
Section: Introductionmentioning
confidence: 99%
“…For a SL-ACHP system, the charge determination experiment was conducted by each method introduced in the previous work. 16 The experimental results under cooling mode showed the intersection of subcooling and superheat curves, which was used to determine the critical charge accurately. The charge determination experiment is always conducted after the ACHP experiment system is set up and the leakage of the system is eliminated.…”
Section: Introductionmentioning