2012
DOI: 10.1016/j.cryogenics.2012.02.004
|View full text |Cite
|
Sign up to set email alerts
|

Investigations of pulsed heat loads on a forced flow supercritical helium loop – Part A: Experimental set up

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
18
0

Year Published

2013
2013
2014
2014

Publication Types

Select...
5
4

Relationship

3
6

Authors

Journals

citations
Cited by 34 publications
(19 citation statements)
references
References 4 publications
1
18
0
Order By: Relevance
“…The HELIOS experimental setup is described in detail in [14], [15]. The 4C model of the HELIOS loop is similar to what was already used for the HELIOS interpretive/validation studies [16], [17], and is shown in FIGURE 2 for the case of scenario 4, see below (for scenario 1b, see again below, the model is the same, except no regulation is applied).…”
Section: Circuit Modelmentioning
confidence: 97%
See 1 more Smart Citation
“…The HELIOS experimental setup is described in detail in [14], [15]. The 4C model of the HELIOS loop is similar to what was already used for the HELIOS interpretive/validation studies [16], [17], and is shown in FIGURE 2 for the case of scenario 4, see below (for scenario 1b, see again below, the model is the same, except no regulation is applied).…”
Section: Circuit Modelmentioning
confidence: 97%
“…In the last couple of years the 4C code and its different modules have undergone a series of successful validation (i.e., comparison with experiments), benchmarking (i.e., comparison with the results of other codes) and application exercises for very different types of transients and systems [5]- [13], including validation against data from the supercritical He (SHe) loop HELIOS at CEA Grenoble [14], [15], operated without [16] or with [17] a controlled bypass valve.…”
Section: Introductionmentioning
confidence: 99%
“…1. This system is a scaled down model (1/20) of the auxiliary cold box of the JT-60SA cryogenic system [4]. It is composed of a closed supercritical helium loop driven by a cold pump which is connected to a saturated helium bath through 2 heat exchangers.…”
Section: Heat Load Smoothing Methodsmentioning
confidence: 99%
“…The vapor is compressed by the cold compressor connected to atmospheric pressure (8). The management of dynamic heat loads has been experimentally validated at CEA Grenoble in the HELIOS facility [3] [4]. The 4.3 K bath is sized such to act as a thermal damper and smooth the thermal loads arriving at the RCB.…”
Section: Cryogenic System Architecturementioning
confidence: 99%