1992
DOI: 10.1016/0032-3861(92)90074-7
|View full text |Cite
|
Sign up to set email alerts
|

Irradiation effects on aromatic polymers: 1. Gas evolution by gamma irradiation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
19
0

Year Published

1999
1999
2023
2023

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 71 publications
(22 citation statements)
references
References 12 publications
3
19
0
Order By: Relevance
“…Nevertheless, these reports seem to contradict with each other, that is, some [1][2][3] have reported that PSF irradiated in vacuum environment are mainly degraded by main chain scission, while others [4,5] reported that cross-linking predominates over scission under vacuum in PSF. Thus, both cross-linking and main chain scission were reported for the irradiation effects on PSF.…”
Section: Introductionmentioning
confidence: 81%
See 2 more Smart Citations
“…Nevertheless, these reports seem to contradict with each other, that is, some [1][2][3] have reported that PSF irradiated in vacuum environment are mainly degraded by main chain scission, while others [4,5] reported that cross-linking predominates over scission under vacuum in PSF. Thus, both cross-linking and main chain scission were reported for the irradiation effects on PSF.…”
Section: Introductionmentioning
confidence: 81%
“…Many studies have investigated irradiation effect on PSF at high temperature [1][2][3][4][5]. Nevertheless, these reports seem to contradict with each other, that is, some [1][2][3] have reported that PSF irradiated in vacuum environment are mainly degraded by main chain scission, while others [4,5] reported that cross-linking predominates over scission under vacuum in PSF.…”
Section: Introductionmentioning
confidence: 87%
See 1 more Smart Citation
“…The radiation stability of crystalline and amorphous PEEK has been extensively studied for the past two decades due to interest in spacecraft applications and nuclear fusion reactors, where the total exposure to radiation ranges between 10 and 50 MGy (i.e., 10,000 -50,000 kGy) [56,67,[69][70][71][72][73][74][75][76][77]. Although degradation and crosslinking of PEEK occur at doses above 10 MGy, it should be appreciated that the exposures of concern to the aerospace and nuclear power industry exceed the standard sterilization doses for medical devices (25-40 kGy) by three orders of magnitude.…”
Section: Chemical Thermal and Radiation Stability: Implications Formentioning
confidence: 99%
“…Table 3. 103.G(gas) for irradiation at 30°C 100 m films vacuum (Hegazy et al, 1992a) www.intechopen.com…”
Section: Effect Of Aromaticity On Radiostabilitymentioning
confidence: 99%