Is the reciprocating movement per se able to improve the cyclic fatigue resistance of instruments?

Abstract: Aim. To compare the effect of brushing motion on torsional and cyclic fatigue resistance of TF Adaptive instruments after clinical use. Methods. 20 packs of TFA small sequence (Sybro-nEndo, Orange, CA, USA) were used for this study and divided into two groups. Each instrument prepared one resin tooth, consisting in 4 canals with a complex anatomy. In group A, no brushing motion was performed. In group B, after the green instrument reached the working length, brushing motion with circumferential filing was perf… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

4
68
0
9

Year Published

2016
2016
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 93 publications
(81 citation statements)
references
References 25 publications
4
68
0
9
Order By: Relevance
“…The dynamic cyclic fatigue model has been previously suggested in order to evaluate the cyclic fatigue fracture resistance of NiTi files (5,10). Indeed, this model approximates to a clinical condition of brushing or pecking motion (12); however, some limitations are observed when using this model.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The dynamic cyclic fatigue model has been previously suggested in order to evaluate the cyclic fatigue fracture resistance of NiTi files (5,10). Indeed, this model approximates to a clinical condition of brushing or pecking motion (12); however, some limitations are observed when using this model.…”
Section: Discussionmentioning
confidence: 99%
“…Different alloys and variations in cross-sectional designs have been suggested to increase the resistance to fatigue fracture and flexibility of these instruments (2,3). Additionally, reciprocating motion kinematics has also been demonstrated to extend the lifespan of a NiTi instrument and its resistance to cyclic fatigue in comparison with continuous rotation movement (2,4,5). In this kinematics, the instruments travel a shorter angular distance compared to in conventional rotary kinematics, which are subject to lower stress values, thus rendering an extended fatigue fracture resistance (4,5).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…As endodontic treatment does not immediately or totally eliminate periapical inflammatory reaction during the procedure itself, harmful substances such as bacterial toxins can escape from the root canal system into the periapex, causing the persistence of pain in the postoperative period 5,6 . Corticosteroids are potent anti-inflammatory drugs that suppress inflammatory phenomena as pain and edema 7 . Thus, the use of this drug is an effective supplement to reduce of these symptons after endodontic treatment8, and its use in the treatment and prevention of pain and endodontic post-treatment swelling has been shown to be effective and safe [8][9][10][11][12][13][14][15][16] .…”
Section: Introductionmentioning
confidence: 99%
“…Canal preparation with reciprocating movement has been shown to reduce file fracture [6][7][8] . The reciprocation-based systems available on the market Reciproc (R) (VDW, Munich, Germany) and WaveOne (WO) (Dentsply Maillefer, Ballaigues, Switzerland)] allow single-file preparation for the entire root canal, thus requiring less time when compared to multi-file rotary systems.…”
Section: Introductionmentioning