Islanding detection method of multi‐port photovoltaic DC micro grid based on harmonic impedance measurement

Abstract: DC Grid does not transmit reactive power, nor does it offer frequency and phase issues. This results in malfunction of conventional islanding detection methods (IDMs) that rely on the above quantities. At present, the DC IDMs proposed in literatures are mostly active power injection methods based on DC/DC converters. However, in a multi-photovoltaic (PV) DC system, the synchronization of the injection of converters is difficult to guarantee, which may lead to detection failure. This paper proposes an impedance… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 30 publications
(11 citation statements)
references
References 38 publications
0
11
0
Order By: Relevance
“…32 Moreover, the impedance limit is difficult to determine as it requires an exact grid impedance although it is extremely irregular and initially unknown. 33 However, in practice, this method is hard to implement.…”
Section: Active Idmsmentioning
confidence: 99%
“…32 Moreover, the impedance limit is difficult to determine as it requires an exact grid impedance although it is extremely irregular and initially unknown. 33 However, in practice, this method is hard to implement.…”
Section: Active Idmsmentioning
confidence: 99%
“…Detection of an islanding condition by monitoring the grid impedance variation is a very effective active AIP technique [19], [24]. The impedance variation is obtained by a perturbation method where a harmonic current (i h,i ) or voltage (v h,i ) signal is injected at the PCC, and the impedance is obtained from responses of the corresponding harmonic voltage (v h,r ) or current (i h,r ) with respect to injected signal as…”
Section: A Analytical Modeling Of the Aip Implementationmentioning
confidence: 99%
“…However, literature [27][28][29][30] only validates IDMs in single-PV grid-connected system. Literature [31] presents an active method based on the DC/DC injection. The islanding detection scheme is formed by estimation of the difference of high frequency impedance before and after the islanding.…”
Section: Introductionmentioning
confidence: 99%