Iterative reconstruction algorithm improves the image quality without affecting quantitative measurements of computed tomography perfusion in the upper abdomen

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(9 citation statements)
references
References 27 publications
0
9
0
Order By: Relevance
“…Woisetschläger et al . ( 14 ) evaluated CT perfusion examinations of the upper abdomen to assess differences in image quality between FBP and ADMIRE Strengths 3, 4 and 5. Quantitative measurements of blood flow, blood volume and time to peak, arterial liver perfusion, portal venous liver perfusion and hepatic perfusion index were generated by placing identical sized ROIs in identical positions in the following tissues; left liver lobe, right liver lobe, hepatocellular carcinoma, spleen, gastric wall, pancreas and portal vein for all four reconstruction types using the maximum-slope model.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Woisetschläger et al . ( 14 ) evaluated CT perfusion examinations of the upper abdomen to assess differences in image quality between FBP and ADMIRE Strengths 3, 4 and 5. Quantitative measurements of blood flow, blood volume and time to peak, arterial liver perfusion, portal venous liver perfusion and hepatic perfusion index were generated by placing identical sized ROIs in identical positions in the following tissues; left liver lobe, right liver lobe, hepatocellular carcinoma, spleen, gastric wall, pancreas and portal vein for all four reconstruction types using the maximum-slope model.…”
Section: Resultsmentioning
confidence: 99%
“…Image quality can be assessed both quantitatively and qualitatively: some of the reviewed publications have included both quantitative and qualitative assessments ( 6 , 8 , 9 , 12 , 13 , 15–17 ) and some only quantitative ( 14 , 16 , 18 , 20 ) or qualitative ( 10 ) assessments. It is apparent from the review that noise reduction measurements cannot be directly transferred into potential dose reduction as IR algorithms are subject to change in noise texture particularly at lower radiation doses, which ultimately affects image quality ( 15 ) .…”
Section: Discussionmentioning
confidence: 99%
“…In our study, the SNR of pancreatic parenchyma, GDA, ASPDA, and DPA in 40-keV MEI (+) increased by 58.14%, 50.76%, 38.66%, and 39.20%, respectively, compared with PEI. Moreover, an advanced modeled iterative reconstruction was applied for DECT to suppress the image noise and improve image quality [ 18 , 19 ]. All these reasons may contribute to the better image quality at 40-keV MEI (+) than PEI.…”
Section: Discussionmentioning
confidence: 99%
“…Images were reconstructed using Advanced Modeled Iterative Reconstruction (ADMIRE)—an iterative postprocessing algorithm [ 16 ], a slice thickness of 3 mm, and convolution kernel of Bv40. Image stacks of the 4-phase CT and CTP scans were generated using ADMIRE 3 and 4, respectively ( Figure 1 ).…”
Section: Methodsmentioning
confidence: 99%
“…Image stacks of the 4-phase CT and CTP scans were generated using ADMIRE 3 and 4, respectively ( Figure 1 ). The latter ADMIRE grade was selected based on preliminary data showing that it yields an image quality roughly comparable to that of 4-phase scans with ADMIRE 3 reconstruction [ 16 ].
Figure 1 Contrast-enhanced cross-sectional images of abdominal 4-phase CT with A) arterial and B) PV phase and reconstructed images from CTP with C) A-CTP and D) PV-CTP phases.
…”
Section: Methodsmentioning
confidence: 99%