2015
DOI: 10.1002/mrm.25975
|View full text |Cite
|
Sign up to set email alerts
|

Joint myocardial T1 and T2 mapping using a combination of saturation recovery and T2‐preparation

Abstract: Purpose To develop a heart-rate independent breath-held joint T1-T2 mapping sequence for accurate simultaneous estimation of co-registered myocardial T1 and T2 maps. Methods A novel preparation scheme combining both a saturation pulse and T2-preparation in a single R-R interval is introduced. The time between these two pulses, as well as the duration of the T2-preparation is varied in each heartbeat, acquiring images with different T1 and T2 weightings, and no magnetization dependence on previous images. Inh… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
90
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
9

Relationship

4
5

Authors

Journals

citations
Cited by 65 publications
(90 citation statements)
references
References 39 publications
0
90
0
Order By: Relevance
“…cMRF is one of several techniques proposed for joint myocardial T 1 and T 2 mapping . Recently, CMR multitasking has been reported for generating motion‐resolved T 1 and T 2 maps with a scan time of 88 s per slice .…”
Section: Discussionmentioning
confidence: 99%
“…cMRF is one of several techniques proposed for joint myocardial T 1 and T 2 mapping . Recently, CMR multitasking has been reported for generating motion‐resolved T 1 and T 2 maps with a scan time of 88 s per slice .…”
Section: Discussionmentioning
confidence: 99%
“…T 1 and T 2 values were measured in region of interests (ROIs) for the phantoms and in vivo experiments. Mean values within the ROI were used to assess accuracy whereas the SD within the ROI (spatial variability) was considered as an indication of the mapping precision in phantom and used as a surrogate for precision in the healthy myocardium measurements . Accuracy of T 1 and T 2 water Dixon‐cMRF was assessed in the standardized T 1 /T 2 phantom study through lines of best fit, determination coefficient, and normalized RMSE (NRMSE) with respect to reference IRSE and MESE measurements.…”
Section: Methodsmentioning
confidence: 99%
“…Cardiac MRF is one of several techniques that can perform simultaneous T 1 and T 2 mapping in the myocardium, including CAIBIRIA (23), QALAS (24), and joint T 1 -T 2 mapping with T 2 -preparation and either saturation (25) or inversion pulses (26). Although the use of interleaved inversions and T 2 preparations is used in other mapping sequences, the MRF paradigm is unique in several ways.…”
Section: Discussionmentioning
confidence: 99%