2013
DOI: 10.1016/j.snb.2012.08.078
|View full text |Cite
|
Sign up to set email alerts
|

Label-free aptamer sensor based on silicon microring resonators

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
91
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 100 publications
(93 citation statements)
references
References 41 publications
2
91
0
Order By: Relevance
“…The signal that resulted from thrombin after 15 minutes incubation time was 317 ± 8.7 pm (mean ± SD). This binding signal is comparable to the value reported by Park et al for a SOI MRR system [13]. The intra-array variations found for aptamer capturing and thrombin binding were similar (CV≈ 2.8%).…”
Section: Resultssupporting
confidence: 88%
See 1 more Smart Citation
“…The signal that resulted from thrombin after 15 minutes incubation time was 317 ± 8.7 pm (mean ± SD). This binding signal is comparable to the value reported by Park et al for a SOI MRR system [13]. The intra-array variations found for aptamer capturing and thrombin binding were similar (CV≈ 2.8%).…”
Section: Resultssupporting
confidence: 88%
“…Fabrication of integrated MRRs has been described in the case of all three main IO main platforms, especially SOI [10,13,14] but also InP [15] and Si 3 N 4 [12,16,17] while realization was also reported for polymer systems [18,19]. The SOI platform offers a large refractive index contrast and therewith a small allowable bend radius and thus footprint.…”
Section: Introductionmentioning
confidence: 99%
“…LoD for anti-BSA recognition is calculated as U w /m detection , which results in 50.8 ng/ml and 5.2 ng/ml for Sample 'A' and Sample 'B', respectively. For the sake of comparison, the latter value is comparable to previous BSA-antiBSA experiments carried out with SU-8 nanopillar cells (2.3 ng/ml) [24], microring resonator biosensor (5.0 ng/ml) [27] and photonic crystal biosensor (26 ng/ml) [28]. Here we note that with FTIR one can obtain much better signal-to-noise ratio and resolution compared with other tools such as a conventional spectrometer.…”
Section: Resultssupporting
confidence: 83%
“…However, because of the time-limiting reason, the treatment was not performed in this work. however, a similar work based on a silicon nanophotonic platform has been successfully studied previously (5), where the radius of operational sensing elements (i.e. the micro-ring) is equal to that of the circularhole defect in our sensing chip.…”
Section: Experimental Analysismentioning
confidence: 97%