1985
DOI: 10.1016/0022-3913(85)90265-3
|View full text |Cite
|
Sign up to set email alerts
|

Laboratory evaluation of a direct reading digital occlusal sensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
8
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(9 citation statements)
references
References 1 publication
0
8
0
1
Order By: Relevance
“…for detecting occlusal contacts in a time sequential manner with the pressure distribution on the occlusal surfaces (Figure 4, Table 2). 41,[46][47][48][49][89][90][91][92][93] Additionally, IOSs can also detect occlusal contact areas (OCAs) (Figure 5). 41 The accuracy of these occlusal analysis systems has been assessed in the dental literature.…”
Section: Computerized Occlusal Analysis Systemsmentioning
confidence: 99%
See 3 more Smart Citations
“…for detecting occlusal contacts in a time sequential manner with the pressure distribution on the occlusal surfaces (Figure 4, Table 2). 41,[46][47][48][49][89][90][91][92][93] Additionally, IOSs can also detect occlusal contact areas (OCAs) (Figure 5). 41 The accuracy of these occlusal analysis systems has been assessed in the dental literature.…”
Section: Computerized Occlusal Analysis Systemsmentioning
confidence: 99%
“…41 The accuracy of these occlusal analysis systems has been assessed in the dental literature. 41,[46][47][48][49][89][90][91][92][93] Computerized occlusal analysis systems provide a reliable method for measuring the OCA at maximum bite force; however, conventional occlusal registration methods seem to provide the highest reliability and validity technique for measuring OCA. 41,48,[91][92][93] F I G U R E 4 Computerized occlusal analysis systems.…”
Section: Computerized Occlusal Analysis Systemsmentioning
confidence: 99%
See 2 more Smart Citations
“…Prilikom metodološkog postupka našeg istraživanja, senzorske folije korišćene su prosečno 10 puta za svakog pacijenta, sa visokom pouzdanošću analize okluzije prilikom svakog merenja. Slične rezultate istraživanja pouzdanosti identifikacije okluzalnih kontakata i mogućnosti višekratne upotrebe T-scan senzorskih folija u kvantitativnoj analizi okluzije objavili su i drugi istraživači242,223,224,225 .Rezultati njihovih istraživanja, ukazuju na to da se isti senzor može koristiti za 4 do 20 snimanja zatvaranja u Ikp, bez izazivanja statistički značajnih razlika između merenja.Okluzija na implantatima predstavlja izuzetno aktuelnu temu o kojoj u literaturi nema mnogo publikacija, ali je opšte prihvaćen stav većine istraživača da je od velikog značaja za dugotrajnost implantata i zubnih nadoknada na njima. Zbog toga je izuzetno važno izabrati objektivnu i pouzdanu metodu za analizu okluzije zubnih nadoknada na implantatima.…”
unclassified