2015
DOI: 10.1039/c4ja00231h
|View full text |Cite
|
Sign up to set email alerts
|

Laser-ablation sampling for inductively coupled plasma distance-of-flight mass spectrometry

Abstract: Laser-ablation (LA) sample introduction is combined with a new simultaneous multi-element determining, velocity-based ICPMS approach called distance-of-flight mass spectrometry (DOFMS).

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
19
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 13 publications
(19 citation statements)
references
References 53 publications
0
19
0
Order By: Relevance
“…The concept of space-focusing in CEA-TOFMS is well established as is the use of a reflectron to mirror the space focus and to partially compensate for ionenergy disparities [23]. The concept of energy-focused CMA was introduced in 2007 [24] and has been applied to both distance-of-flight MS (DOFMS) [25][26][27][28][29][30][31] and TOFMS [22,32,33].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The concept of space-focusing in CEA-TOFMS is well established as is the use of a reflectron to mirror the space focus and to partially compensate for ionenergy disparities [23]. The concept of energy-focused CMA was introduced in 2007 [24] and has been applied to both distance-of-flight MS (DOFMS) [25][26][27][28][29][30][31] and TOFMS [22,32,33].…”
Section: Introductionmentioning
confidence: 99%
“…The 40.68 MHz ICP ionization source (crystal-controlled, model HF 2000F; PlasmaTherm Inc., Kresson, NJ, USA) used in this study has been previously described in detail [29,30]. Commercially available analytical reagent grade 1000 ppm stock solutions or analytical reagent grade nitrate salts (from several different manufacturers) were used to prepare all sample and standard solutions.…”
Section: Sample Preparation Introduction and Ionizationmentioning
confidence: 99%
“…ince the development of distance-of-flight mass spectrometry (DOFMS) theory by Enke and Dobson [1], several papers have shown its experimental viability [2][3][4][5][6][7][8][9]. Conceptually, mass-to-charge (m/z) separation in DOFMS is similar to that in time-of-flight mass spectrometry (TOFMS), while the ion detection process resembles that of spatially dispersive, sectorfield mass spectrometry (SFMS).…”
mentioning
confidence: 99%
“…The MCP/phosphor assembly has a 4.0-cm active length [2] and, in combination with a CCD camera, provides a linear dynamic range (LDR) of five orders of magnitude [5] and a full-width at half-maximum mass resolving power (RP FWHM ) of approximately 500 [6]. However, the MCP/phosphor screen detector must be coupled to a scientific camera for massspectral acquisition [2], suffers an inherent mass bias due to the MCPs, and does not detect the true mass-spectral peak width because of secondary electron amplification and resulting Coulombic repulsion [5].…”
mentioning
confidence: 99%
See 1 more Smart Citation