1984
DOI: 10.1152/jappl.1984.56.3.798
|View full text |Cite
|
Sign up to set email alerts
|

Laser-Doppler measurement of skin blood flow: comparison with plethysmography

Abstract: We compared laser-Doppler velocimetry with plethysmographically determined changes in skin blood flow (SkBF) in five studies on four men. Increments in SkBF were induced by raising whole-body skin temperature to 39 degrees C for 50-70 min. We found laser-Doppler blood flow (LDF) to correlate well with total forearm blood flow (FBF) within each study (r = 0.94-0.98), but the relationship varied among studies. Thus the slopes for the LDF vs. FBF relationship varied from 40 to 122 mV X ml-1 X 100 ml X min. The va… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
129
1
4

Year Published

1986
1986
2014
2014

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 213 publications
(137 citation statements)
references
References 26 publications
3
129
1
4
Order By: Relevance
“…Laser Doppler blood flow was recorded in millivolts, which are directly related to blood flow in the microcirculation of the surface tissue (17). Absolute blood flow, in ml/minute/100 gm of tissue, can be approximated by multiplying the laser Doppler signal, in millivolts, by 4.…”
Section: Methodsmentioning
confidence: 99%
“…Laser Doppler blood flow was recorded in millivolts, which are directly related to blood flow in the microcirculation of the surface tissue (17). Absolute blood flow, in ml/minute/100 gm of tissue, can be approximated by multiplying the laser Doppler signal, in millivolts, by 4.…”
Section: Methodsmentioning
confidence: 99%
“…Thus, the purpose of this study was to determine if there are gender differences in local or central control of cutaneous blood flow that could account for the increased incidence of Raynaud's disease in women. 4 To measure hand blood flow, a water-filled plethysmograph was used. The water temperature of the plethysmograph was thermostatically controlled and continuously monitored and could be adjusted to warm or cool the hand.…”
mentioning
confidence: 99%
“…Cold induces vasoconstriction in cutaneous tissue and this has been confirmed by laser Doppler flowmetry, 6 strain gauge plethysmography 7 and finger skin temperature. 8,9 Adrenergic function is thought to be involved in this coldinduced vasoconstriction, because inhibition of sympathetic adrenergic function significantly reduces the cutaneous vasoconstrictor response to direct local cooling.…”
Section: Vascular Response To Cold Exposure (Vasoconstriction and Vasmentioning
confidence: 78%