1996
DOI: 10.1118/1.597725
|View full text |Cite
|
Sign up to set email alerts
|

Laser heating of thermoluminescent plates: Application to intraoperative radiotherapy

Abstract: A new system of radiation dose mapping based on laser heating of thermoluminescent dosimetric plates (TLDP) has been developed. Application of this technique to intraoperative radiotherapy (IORT) has been investigated. Preliminary results show that TLDP are a possible alternative to radiological films and ionization chambers since they provide some advantages such as 2D dose measurements with digital storage, large dynamic dose range, and easy processing.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
2
0
1

Year Published

1997
1997
2006
2006

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 0 publications
0
2
0
1
Order By: Relevance
“…Il est ainsi possible de lire des plaques thermoluminescentes avec une résolution inférieure au millimètre, la taille minimale des pixels étant limitée par la diffusion thermique au niveau du point chauffé par le laser. Toutefois, en dépit de temps de lecture pénalisants (environ 30 minutes), d'un lecteur lourd et d'utilisation très délicate, ces systèmes ont permis de démontrer l'intérêt de la cartographie de dose pour la caractérisation de faisceaux de particules et la mesure 2D dans des géométries complexes (Albert et al, 1997 ;Setzkorn et al, 1997Setzkorn et al, , 1996Beteille et al, 1996 ;Prévost et al, 1995 ;Setzkorn, 1995 ;Vignolo, 1994 ;Sevière, 1993).…”
Section: Introductionunclassified
“…Il est ainsi possible de lire des plaques thermoluminescentes avec une résolution inférieure au millimètre, la taille minimale des pixels étant limitée par la diffusion thermique au niveau du point chauffé par le laser. Toutefois, en dépit de temps de lecture pénalisants (environ 30 minutes), d'un lecteur lourd et d'utilisation très délicate, ces systèmes ont permis de démontrer l'intérêt de la cartographie de dose pour la caractérisation de faisceaux de particules et la mesure 2D dans des géométries complexes (Albert et al, 1997 ;Setzkorn et al, 1997Setzkorn et al, , 1996Beteille et al, 1996 ;Prévost et al, 1995 ;Setzkorn, 1995 ;Vignolo, 1994 ;Sevière, 1993).…”
Section: Introductionunclassified
“…Laser-heated thermoluminescence dosimetry was first demonstrated on thin layers of powdered ceramics [1], and the combination of thermoluminescence and heat-transfer issues for this have been analysed [2]. This has applications in medicine [3,4]. Laser heating of the sample is interesting for three reasons.…”
Section: Introductionmentioning
confidence: 99%
“…Dosimetry systems utilized in previously reported IORT studies include: ͑a͒ diodes, [20][21][22][23][24][25][26] ͑b͒ small volume ionization chambers, 20,22,23,[27][28][29][30][31][32][33][34] ͑c͒ film, [22][23][24]26,29,32,33,35 and ͑d͒ thermoluminescent dosimetric plates. 36 The aim of the present study is to examine the validity of using p-type silicon diodes for measurements of relative absorbed dose distributions in degraded electron beams for IORT. A comparison of a diode and a diamond detector measurement of IORT dose distributions is made using the latter detector as a reference.…”
Section: Introductionmentioning
confidence: 99%