1997
DOI: 10.1016/s0584-8547(97)00083-9
|View full text |Cite
|
Sign up to set email alerts
|

Laser-induced fluorescence of As, Se and Sb in the inductively coupled plasma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

1999
1999
2020
2020

Publication Types

Select...
5
1
1

Relationship

2
5

Authors

Journals

citations
Cited by 16 publications
(12 citation statements)
references
References 21 publications
0
12
0
Order By: Relevance
“…These wavelengths are necessary for As and Se, where the ® rst excited state can be reached only with wavelengths less than 200 nm . Anti-Stokes Raman shifting of 230 nm radiation has been utilized effectively for laser-induced¯uorescence measurem ents of As and Se in the inductively coupled plasma (ICP) 5 and electrotherm al atomizers, 6 but remains to be utilized for LEI m easurements of these elements.…”
Section: Introductionmentioning
confidence: 99%
“…These wavelengths are necessary for As and Se, where the ® rst excited state can be reached only with wavelengths less than 200 nm . Anti-Stokes Raman shifting of 230 nm radiation has been utilized effectively for laser-induced¯uorescence measurem ents of As and Se in the inductively coupled plasma (ICP) 5 and electrotherm al atomizers, 6 but remains to be utilized for LEI m easurements of these elements.…”
Section: Introductionmentioning
confidence: 99%
“…Both schemes have been evaluated previously for direct solution measurem ents in the ICP and ETA. Limits of detection (LODs) of 4 ng/m L for As and 2 ng/m L for Se have been reported in the ICP, 15 while LODs of 0.02 ng/ mL for As and 0.02 ng/m L for Se have been reported in the ETA. 16 In earlier work, saturation energies of As (2± 4 m J) and Se (1±2 m J) were determined in the ICP and ETA atomizers.…”
Section: Resultsmentioning
confidence: 99%
“…The laser instrumentation used in these studies was the same as that employed previously. 15,16 Brie¯y, a XeF excimer laser (L PX 210i, Lambda Physik, Ft. Lauderdale, FL ) operating at 351 nm provides up to 350 mJ per pulse at repetition rates of up to 100 Hz. The output of the excimer was used to pump a dye laser (Scanmate 2, Lambda Physik) operating near 460 nm to produce radiation near 230 ±235 nm by frequency doubling in a BBO I cr ystal.…”
Section: Exp Erim Entalmentioning
confidence: 99%
See 1 more Smart Citation
“…Here, absorption by oxygen in air or by other molecules may hamper detection. Nevertheless, detection of these elements by atomic LIF in atmospheric pressure acetylene/air flames has been demonstrated [296] using tunable (dye) laser radiation in the range 193e213 and detecting the elements off-resonance.…”
Section: Laser Induced Fluorescencementioning
confidence: 99%