1968
DOI: 10.1007/978-3-7091-4527-2_22
|View full text |Cite
|
Sign up to set email alerts
|

Laser-Mikro-Emissionsspektralanalyse in verschiedenen Wellenlängenbereichen

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
1
0
1

Year Published

1970
1970
1984
1984

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(2 citation statements)
references
References 11 publications
0
1
0
1
Order By: Relevance
“…The atomic vapour or plasma torch created in this way is used as the source in laser optical emission spectrometry (LOES) (Moenke andMoenke-Blankenburg 1968, Seeley andSkogerboe 1974), mass spectrometry (MS) (see (i 2.13), or as the absorption volume in atomic absorption spectrometry (AAS) (Mossotti et a1 1967, K6nig andNeumann 1976). The analytical performance is determined by the detection principle (OES, MS, AAS) used; the capability for in-depth ( 5 3.2.3) and lateral resolution is limited by the dimensions of the laser crater or the sample thickness to the Ax, y, z 3 1 p m range, i.e.…”
Section: Laser Optical Emission Spectrometry Loes Some Methods Have B...mentioning
confidence: 99%
“…The atomic vapour or plasma torch created in this way is used as the source in laser optical emission spectrometry (LOES) (Moenke andMoenke-Blankenburg 1968, Seeley andSkogerboe 1974), mass spectrometry (MS) (see (i 2.13), or as the absorption volume in atomic absorption spectrometry (AAS) (Mossotti et a1 1967, K6nig andNeumann 1976). The analytical performance is determined by the detection principle (OES, MS, AAS) used; the capability for in-depth ( 5 3.2.3) and lateral resolution is limited by the dimensions of the laser crater or the sample thickness to the Ax, y, z 3 1 p m range, i.e.…”
Section: Laser Optical Emission Spectrometry Loes Some Methods Have B...mentioning
confidence: 99%
“…A LIBS technikában rejlő analitikai potenciált felismerve a német Zeiss és az amerikai Jarell-Ash cégek 1964 és 1967 között megkezdték a kereskedelmi forgalom számára szánt első LIBS berendezések kifejlesztését [5]. A 60-as években rendelkezésre álló technológia viszont sajnos nem tette lehetővé az akkoriban elterjedt szikrakisülési atomemissziós spektroszkópiához hasonló pontosság illetve precizitás elérését, ennélfogva a lézerablációs rendszerek hosszú ideig csupán mintabeviteli rendszerként szolgáltak más atomspektroszkópiai berendezések számára [6,7].…”
Section: Irodalmi áTtekintés 21 a Lézer Indukált Plazma Spektroszkópi...unclassified