2016
DOI: 10.1016/j.ijpharm.2015.10.006
|View full text |Cite
|
Sign up to set email alerts
|

Laser-triggered intraocular implant to induce photodynamic therapy for posterior capsule opacification prevention

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
18
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 23 publications
(18 citation statements)
references
References 25 publications
0
18
0
Order By: Relevance
“…Even with the improved skills and new technologies, PCO still is the most common complication following an uneventful cataract surgery. Great efforts have been expended to reduce the rate of PCO, including pharmacologic measures, 21 , 22 surgical techniques, 31 devices, 23 28 preventive laser treatment, 32 , 33 IOL materials, 13 , 18 , 31 , 34 , 35 and IOL designs. 12 19 , 36 Adding a sharp posterior edge to IOLs has reduced significantly the PCO rates and the subsequent need for Nd:YAG laser capsulotomy.…”
Section: Discussionmentioning
confidence: 99%
“…Even with the improved skills and new technologies, PCO still is the most common complication following an uneventful cataract surgery. Great efforts have been expended to reduce the rate of PCO, including pharmacologic measures, 21 , 22 surgical techniques, 31 devices, 23 28 preventive laser treatment, 32 , 33 IOL materials, 13 , 18 , 31 , 34 , 35 and IOL designs. 12 19 , 36 Adding a sharp posterior edge to IOLs has reduced significantly the PCO rates and the subsequent need for Nd:YAG laser capsulotomy.…”
Section: Discussionmentioning
confidence: 99%
“…To date, much effort has been devoted to develop intraocular lens (IOLs), e.g., irrigating with chemical drugs, or genes, which can be in situ released to inhibit LECs proliferation after surgery. However, the released free drugs/genes have serious toxicity to other normal cells,[8c,10] which limit the clinical trial. Some modifications of the lens based on shape feature, hydrophilic–hydrophobic property, et al are less therapeutic effect on PCO.…”
Section: Methodsmentioning
confidence: 99%
“…Several methods have been suggested to produce coatings on drug-eluting biomedical devices (e.g., layer-by-layer deposition, spray coating, dip coating, plasma-assisted grafting) with the purpose of implementing drug-eluting reservoirs [64][65][66][67][68][69][70][71][72][73]. Besides, these coatings may be used in order to increase the hydrophilicity of the device surface [74] and, also, as diffusion barriers to drug release [75][76][77]. The main concern with the design of coatings to be applied onto CLs or IOLs is the preservation of the optical properties of the original lenses.…”
Section: Coatingmentioning
confidence: 99%
“…Zhang et al [77] obtained the laser-triggered release of indocyanine green, a photosensitizer, from commercially available IOLs by spray-coating the active agent on the lens surface and, subsequently, controlling the release with a sealing layer of PLGA. However, low transmittance, related to both the presence of indocyanine green and to PLGA degradation, remained an issue over several weeks after immersion in PBS, affecting the suitability of the system for the intended ocular application.…”
Section: Cataractmentioning
confidence: 99%