2020
DOI: 10.1007/s00604-020-04338-z
|View full text |Cite
|
Sign up to set email alerts
|

Lateral flow immunoassay for 5-hydroxyflunixin based on near-infrared fluorescence molecule as an alternative label to gold nanoparticles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 17 publications
(8 citation statements)
references
References 23 publications
0
8
0
Order By: Relevance
“…A detector in the device senses the light that the dye or the marker emits. Correct sensing is very important to quantify the target molecule as the amount of the target analyte in the sample immediately correlates with the produced light intensity [17][18][19]. In some cases, the target analyte concentration in the sample is estimated by comparing the intensity of the fluorescent signal to a reference signal [20].…”
Section: Working Principlementioning
confidence: 99%
See 1 more Smart Citation
“…A detector in the device senses the light that the dye or the marker emits. Correct sensing is very important to quantify the target molecule as the amount of the target analyte in the sample immediately correlates with the produced light intensity [17][18][19]. In some cases, the target analyte concentration in the sample is estimated by comparing the intensity of the fluorescent signal to a reference signal [20].…”
Section: Working Principlementioning
confidence: 99%
“…The light source plays a critical role in providing the required energy for light emission by the target molecule excited in the sample kept within the lateral flow immunoassay test strip. Common light sources are light-emitting diodes [18,[45][46][47] and laser diodes [48,49]. A light-emitting diode (LED) is a solidstate, stable, and compact source producing light when a current is applied.…”
Section: Light Sourcementioning
confidence: 99%
“…14 By using 5-FLU as a hapten coupled to bovine serum albumin (BSA) to prepare an immunogen, Fan et al obtained a monoclonal antibody (mAb) with an IC 50 of 3.2 ng mL −1 for 5-FLU and 3.3 ng mL −1 for FLU. 1 Although this mAb had a broad specificity, it had low affinity for both FLU and 5-FLU. We can conclude that the antibodies prepared in these studies demonstrate either low affinity or unclear broad specificity recognition to both FLU and 5-FLU.…”
Section: Introductionmentioning
confidence: 99%
“…Nevertheless, it was reported to be limited by two major aspects: low sensitivity and inability to analyze quantitatively (Bahadir and Sezginturk, 2016). Thus, numerous methods have been developed to solve the problems such as fluorescence, surface plasmon resonance, and chemiluminescence (Cui et al, 2015;Fan et al, 2020;Kim K et al, 2021). However, these developed methods have not satisfied the detection limit and precision applicable to clinical practice so far.…”
Section: Introductionmentioning
confidence: 99%