2009
DOI: 10.1365/s10337-009-1032-0
|View full text |Cite
|
Sign up to set email alerts
|

LC–MS Simultaneous Determination of Itopride Hydrochloride and Domperidone in Human Plasma

Abstract: A simple, rapid, cost-effective, and sensitive TLC-spectrodensitometric method for simultaneous determination of esomeprazole and domperidone was developed and tested in human plasma. Ethyl acetate: methanol: benzene: acetonitrile (5: 4: 8: 3, v/v/v/v) mobile phase was used for separation on TLC plates detected at 286 nm. The linearity ranges were 5-1200 and 2-600 ng/ spot for esomeprazole and domperidone, and limits of detection were 1.73 and 0.59 ng/spot. The effects of four variables affecting R f were eval… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
9
0

Year Published

2010
2010
2015
2015

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(9 citation statements)
references
References 15 publications
0
9
0
Order By: Relevance
“…A liquid chromatography coupled with tandem mass spectrometric (LC‐MS/MS) method providing an LLOQ of 0.189 ng/mL using an 800 μL plasma sample was used for the quantification of domperidone in human plasma (Smit et al ., ). Some other assays based on LC‐MS/MS (Bose et al ., ; Wu et al ., ; Zhang et al ., ) were also described for determining domperidone in human plasma. Xu et al .…”
Section: Introductionmentioning
confidence: 99%
“…A liquid chromatography coupled with tandem mass spectrometric (LC‐MS/MS) method providing an LLOQ of 0.189 ng/mL using an 800 μL plasma sample was used for the quantification of domperidone in human plasma (Smit et al ., ). Some other assays based on LC‐MS/MS (Bose et al ., ; Wu et al ., ; Zhang et al ., ) were also described for determining domperidone in human plasma. Xu et al .…”
Section: Introductionmentioning
confidence: 99%
“…Gastro‐esophageal reflux disease (GERD) is one of the most prevalent upper gastrointestinal disorders . A combination of itopride and domperidone performs better in GERD due to a blockade of the dopamine D2 receptor and inhibition of acetylcholine esterase .…”
Section: Introductionmentioning
confidence: 99%
“…Several methods have been reported for the determination of DOM including potentiometry , anodic differential pulse voltammetry , HPLC‐MS and HPLC with fluorescence detection . Only one analytical method has been reported for the simultaneous determination of ITP and DOM using HPLC with MS detection . However, the reported method requires expensive and sophisticated equipment that is not easily available.…”
Section: Introductionmentioning
confidence: 99%
“…Quite a lot of analytical methods were reported for the determination of Itopride hydrochloride in its pure form, pharmaceutical preparations and human plasma, including spectrophotometric methods [3][4][5], electrochemical method [6], TLC [7], liquid chromatography with ultraviolet detection [8][9][10][11][12], chemiluminescence detection [13] and fluorescence detection [14][15][16]. On the other hand, RB was analyzed by applying several methods like; spectrophotometric methods [17][18][19][20][21][22], chemometric method [23] and spectroflourimetric methods [24,25].…”
Section: Introductionmentioning
confidence: 99%