Leadless Cardiac Pacemakers: Pacing Paradigm Change

Abstract: Traditional transvenous approach for permanent cardiac pacing can be associated with significant acute and chronic complications related partly to either the insertion of transvenous lead or subcutaneous placement of pacemaker device. We summarize the current status of a novel self-contained leadless cardiac pacemaker in the first-in-human and subsequent series of feasibility studies in patients indicated for ventricular rate-responsive pacing (VVI). Using a femoral venous approach, the device is implanted at … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0
3

Year Published

2016
2016
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(10 citation statements)
references
References 31 publications
0
7
0
3
Order By: Relevance
“…4 Leadless pacemakers were designed to reduce complications associated with transvenous pacemakers, particularly lead-and pocket-related complications, which historically have been reported to range as high as 2%-12%. 5,6 Leadless pacemakers have demonstrated a high safety and efficacy profile. 7 However, first-generation leadless pacemakers deliver only ventricular pacing (VVI[R] mode), which largely limits their use to patients with bradycardia and chronic AF and those considered to be at high risk for complications related to implantation of a leaded pacemaker.…”
Section: Introductionmentioning
confidence: 99%
“…4 Leadless pacemakers were designed to reduce complications associated with transvenous pacemakers, particularly lead-and pocket-related complications, which historically have been reported to range as high as 2%-12%. 5,6 Leadless pacemakers have demonstrated a high safety and efficacy profile. 7 However, first-generation leadless pacemakers deliver only ventricular pacing (VVI[R] mode), which largely limits their use to patients with bradycardia and chronic AF and those considered to be at high risk for complications related to implantation of a leaded pacemaker.…”
Section: Introductionmentioning
confidence: 99%
“…More than 55 years ago, the first cardiac pacemaker was implanted in the heart [19]. Since then, this device has been developed into a more reliable device by adding battery lifetime, improving lead performance and enhancing device capability (i.e.…”
Section: Leadless Cardiac Pacemaker (Lcp) As a New Minimal Invasive Mmentioning
confidence: 99%
“…In addition, implantation procedures of this regular pacemaker also have several risks. In the short-term, it can cause mobility limitations, pneumothorax, cardiac tamponade and upper limb Deep Vein Thrombosis (DVT) [3,4,6,19]. A study showed that up to six out of ten patients with regular pacemakers developed mobility limitations in the shoulder region, where the pulse generators were implanted [6].…”
Section: Leadless Cardiac Pacemaker (Lcp) As a New Minimal Invasive Mmentioning
confidence: 99%
See 1 more Smart Citation
“…The prevalence of heart conduction disorders requiring implantation of a permanent pacemaker is increasing as the population is aging. Nevertheless, despite all technological improvements over the last 6 decades, conventional pacing therapy is still associated with a complications rate ranging from 1% to 12.4% in the first 2‐month post implantation and reported up to 19.7% at 5‐year follow‐up 1–4 …”
Section: Introductionmentioning