Pipeline leak detection using hydraulic transient analysis is a relatively new detection technique. For single pipeline systems, recent work has led to two different approaches for determining leak parameters based on leak-induced patterns displayed in a pipeline's frequency response diagram (FRD). The major difference between the two techniques is that one uses the leak-induced pattern within the odd harmonics of an FRD, while the other one uses the leak-induced pattern at the even harmonics. In order to compare and contrast the two approaches, the current research analyses the relationship between the characteristics of the leak-induced patterns and the parameters of the pipeline system. A dimensionless analysis, based on hydraulic impedance, is adopted to simplify the equations. The amplitudes of leak-induced patterns at both the odd and the even harmonics in the FRD are found to be dependent on a critical parameter: the dimensionless steady-state valve impedance, Z and the amplitude of either leak-induced pattern. Finally, the two existing FRD-based leak detection methods are compared, and the approach using the odd harmonics is found to be superior.