2013 Brazilian Power Electronics Conference 2013
DOI: 10.1109/cobep.2013.6785164
|View full text |Cite
|
Sign up to set email alerts
|

Leakage current minimization techniques for single-phase transformerless grid-connected PV inverters — An overview

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
15
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 21 publications
(15 citation statements)
references
References 21 publications
0
15
0
Order By: Relevance
“…In the given system, a damping resistor R CM2 is connected between grid and neutral point capacitor. Additionally, two chokes, L CM1 and L CM2 , and three Y-connected capacitors, C CM2 , are connected for filter purposes [12][13][14]. R CM1 and C CM1 are connected between the grid and negative terminal of the DC link.…”
Section: Filtering Of Common Mode Voltagementioning
confidence: 99%
See 1 more Smart Citation
“…In the given system, a damping resistor R CM2 is connected between grid and neutral point capacitor. Additionally, two chokes, L CM1 and L CM2 , and three Y-connected capacitors, C CM2 , are connected for filter purposes [12][13][14]. R CM1 and C CM1 are connected between the grid and negative terminal of the DC link.…”
Section: Filtering Of Common Mode Voltagementioning
confidence: 99%
“…The CM loop impedance can be increased in order to suppress current in CM loop effectively. In [13], the mid-point of DC and AC side voltage nodes are connected to the proposed new CM internal loop scheme in order to suppress CMC. In [14], a novel modulation scheme is presented to control inverter power switches in order to reduce CMC.…”
mentioning
confidence: 99%
“…In three phase motor drive system the passive common mode filter has been widely used [14] and its application in grid-connected PV system is also researched recently [15] [16]. Fig.…”
Section: Leakage Current Supression With Bypass Capacitormentioning
confidence: 99%
“…In recent years, some scholars have proposed to set CM internal loop at the output side of the system to suppress CM current. In [8], a CM internal loop is proposed by connecting the midpoint of ac side voltage to the dc side voltage point. In [9], a new modulation method is proposed for optimally controlling the power switches of transformerless single-phase full-bridge PV inverters to reduce CM current.…”
Section: Introductionmentioning
confidence: 99%
“…In [10], the RC absorption branch is added between the output terminal and the dc negative bus to form a single CM internal loop. However, there is no further analysis of CM current in [8][9][10], and there is no comparative analysis of the effect of CM internal loop on the high frequency component of the CM current. Furthermore, it is easy to produce high frequency resonance in the CM circuit by using the single CM internal loop method so that the large CM current of the resonant frequency will be produced.…”
Section: Introductionmentioning
confidence: 99%