2019
DOI: 10.2217/fca-2019-0040
|View full text |Cite
|
Sign up to set email alerts
|

Lifetech LAmbre: A New Promising and Novel Device in the Interventional Stroke Prevention

Abstract: The advances in the left atrial appendage closure as a stroke prevention method in patients with atrial fibrillation and contraindications to oral anticoagulants made a huge revolution offering a great alternative for patients with a high risk of bleeding. The nitinol-based, self-expanding LAmbre closure system shows promising initial results in terms of efficacy and safety in worldwide different clinical trials offering an alternative to the known Amulet and Watchman closure systems. Lifetech received CE Mark… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 18 publications
0
4
0
Order By: Relevance
“…The main finding of the present report is that in patients with AF-related LAA thrombus and contraindications or lack of response to oral anticoagulation, LAA closure supported by a cerebral protection system to minimize the risk of cerebral ischemic lesions represents an efficient alternative treatment. Moreover, the double-umbrella design of the LAmbre device could constitute an advantage for these patients, allowing minimal LAA manipulation during implantation [ 15 ].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The main finding of the present report is that in patients with AF-related LAA thrombus and contraindications or lack of response to oral anticoagulation, LAA closure supported by a cerebral protection system to minimize the risk of cerebral ischemic lesions represents an efficient alternative treatment. Moreover, the double-umbrella design of the LAmbre device could constitute an advantage for these patients, allowing minimal LAA manipulation during implantation [ 15 ].…”
Section: Discussionmentioning
confidence: 99%
“…Thus, intraprocedural systemic embolization can still have serios consequences and cautious manipulation of the LAA closure device is recommended. The double-umbrella design of the LAmbre device might be a substantial advantage in preventing intraprocedural thrombus migration, allowing for partial device deployment at the LAA ostium, followed by complete delivery inside the appendage [ 15 , 29 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The implant is a nitinol-based, self-expanding device comprising a hook-embedded umbrella with a short central waist. The waist acts as an articulating, compliant connection between the cover and the umbrella, allowing the cover to self-orient the cardiac wall [ 18 ].…”
Section: Methodsmentioning
confidence: 99%