2021
DOI: 10.1016/j.epsr.2021.107231
|View full text |Cite
|
Sign up to set email alerts
|

Linear power flow formulations and optimal operation of three-phase autonomous droop-controlled Microgrids

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
9
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(9 citation statements)
references
References 19 publications
0
9
0
Order By: Relevance
“…The autonomous voltage inverter was implemented in the block "Inverter". The inverter scheme was selected with the block of PWM implementation [46][47][48]. As [38,43] propose a mathematical model of an asynchronous electric motor and [46][47][48] propose that of an autonomous voltage inverter, it was deemed unnecessary to provide these mathematical models in the present work.…”
Section: Adaptation Of the Existing Vector Control And Direct Torque ...mentioning
confidence: 99%
See 2 more Smart Citations
“…The autonomous voltage inverter was implemented in the block "Inverter". The inverter scheme was selected with the block of PWM implementation [46][47][48]. As [38,43] propose a mathematical model of an asynchronous electric motor and [46][47][48] propose that of an autonomous voltage inverter, it was deemed unnecessary to provide these mathematical models in the present work.…”
Section: Adaptation Of the Existing Vector Control And Direct Torque ...mentioning
confidence: 99%
“…The inverter scheme was selected with the block of PWM implementation [46][47][48]. As [38,43] propose a mathematical model of an asynchronous electric motor and [46][47][48] propose that of an autonomous voltage inverter, it was deemed unnecessary to provide these mathematical models in the present work. The parameters of the traction motor and autonomous voltage inverter required to implement the simulation model are provided in Tables 1 and 2, respectively.…”
Section: Adaptation Of the Existing Vector Control And Direct Torque ...mentioning
confidence: 99%
See 1 more Smart Citation
“…Control scheme required running values of current and voltage coming out of filter unit for shaping of both AC current and voltage provided by inverter unit. The entire closed loop control technique provides additional phase angle regulation between AC voltage and current to minimize flow of reactive power [23]. THD of provided current from inverter unit maintain its value in-between 1-2 depending on THD of grid voltage in grid-tied low voltage AC-microgrid system.…”
Section: Control Scheme Of Pv Invertermentioning
confidence: 99%
“…Remolino et al 22 developed a simple LF method involving backward and forward for distribution systems possessing a number of PV nodes. Bassey et al 23 presented two linear LF methods involving approximations on current injections and distribution LF formulations, for islanded droopcontrolled microgrids. The method is non-iterative and can be extended to optimal LF.…”
mentioning
confidence: 99%