Bailey's Industrial Oil and Fat Products 2005
DOI: 10.1002/047167849x.bio050
|View full text |Cite
|
Sign up to set email alerts
|

Lipid Oxidation: Measurement Methods

Abstract: Numerous analytical methods are routinely used for measuring lipid oxidation in foods. However, there is no uniform and standard method for detecting all oxidative changes in all food systems. Therefore, it is necessary to select a proper and adequate method for a particular application. The available methods to monitor lipid oxidation in foods can be classified into five groups based on what they measure: the absorption of oxygen, the loss of initial substrates, the formation of free radicals, and the format… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

3
123
0
3

Year Published

2012
2012
2020
2020

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 160 publications
(129 citation statements)
references
References 116 publications
3
123
0
3
Order By: Relevance
“…TOTOX values refl ect contents of both hydroperoxides and their breakdown products, and provide a better estimation of the progressive oxidative deterioration of fats e.g. during storage [Shahidi & Zhong, 2005;Mildner-Szkudlarz et al, 2009]. Exactly the same tendency as for AV was observed for TOTOX in the case of both margarine and butter cookies.…”
Section: Sensory Analysis By Expertsmentioning
confidence: 71%
See 2 more Smart Citations
“…TOTOX values refl ect contents of both hydroperoxides and their breakdown products, and provide a better estimation of the progressive oxidative deterioration of fats e.g. during storage [Shahidi & Zhong, 2005;Mildner-Szkudlarz et al, 2009]. Exactly the same tendency as for AV was observed for TOTOX in the case of both margarine and butter cookies.…”
Section: Sensory Analysis By Expertsmentioning
confidence: 71%
“…In butter cookies, only the content of 100 mg of CPE caused the inhibition of oxidative changes till the 12 th week of storage. The anisidine value (AV) is an indicator of the concentration of secondary lipid oxidation products generated during the decomposition of hydroperoxides [Shahidi & Zhong, 2005]. These unstable compounds were consequently broken down by a free radical mechanism to give hydroxyl free radical and lots of other compounds -alcohols, aldehydes, ketones a Values are expressed as means ± SD of 3 independent assays.…”
Section: Sensory Analysis By Expertsmentioning
confidence: 99%
See 1 more Smart Citation
“…Indeed, the oxidation of the oils leads to the formation of hydroperoxides, primary products of oxidation. Thus, the peroxide value corresponding to the hydroproxide content represents a very useful and very sensitive criterion for assessing the first stages of the oxidative deterioration of a fatty substance and an oil during production and storage [58] [59]. This standard method is included in the specifications for "fatty substances" with a threshold value of 10 meq O 2 per kg of material for a refined oil [58] [60].…”
Section: Chemical Propertiesmentioning
confidence: 99%
“…Phenolic antioxidants form a radical with low reactivity, due to delocalization of the unpaired electron over the aromatic ring, and exhibit no further potential to react with lipids after hydrogen abstraction. 5 Consumption of food items rich in antioxidant is recommended by several studies to augment array of free radical scavengers inside the body. To combat excess of free radicals, nutraceutical antioxidants as dietary supplements exerting positive pharmacological effects on specific human diseases must be explored.…”
mentioning
confidence: 99%