Lipidomics 2012
DOI: 10.1002/9783527655946.ch1
|View full text |Cite
|
Sign up to set email alerts
|

Lipidomics Perspective: From Molecular Lipidomics to Validated Clinical Diagnostics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
20
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 16 publications
(20 citation statements)
references
References 40 publications
0
20
0
Order By: Relevance
“…Based on the high resolution performance and accurate mass values obtained using the Orbitrap, the sum compositions 25 of the glycerolipid, sphingolipid, cholesterol, cholesterol ester and PI lipid ions, including (i) assignment of the head group identities, (ii) the nature of their hydrophobic chain linkages (i.e., diacyl versus plasmanyl- or plasmenyl-ether) and (iii) the total number of carbons and double bonds that were present within their hydrophobic chains, could be automatically assigned by in silico comparison with the calculated masses of a database of hypothetical lipid compounds, using the LIMSA software (Table 1 and Supplemental Tables 1–15). For example, m/z 850.7857 in Figure 1A was assigned as the ammonium ion adduct of a TG (50:1) lipid (calculated m/z 850.7858), with the experimental and calculated m/z values differing by only 0.0001 Da (0.08 ppm).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Based on the high resolution performance and accurate mass values obtained using the Orbitrap, the sum compositions 25 of the glycerolipid, sphingolipid, cholesterol, cholesterol ester and PI lipid ions, including (i) assignment of the head group identities, (ii) the nature of their hydrophobic chain linkages (i.e., diacyl versus plasmanyl- or plasmenyl-ether) and (iii) the total number of carbons and double bonds that were present within their hydrophobic chains, could be automatically assigned by in silico comparison with the calculated masses of a database of hypothetical lipid compounds, using the LIMSA software (Table 1 and Supplemental Tables 1–15). For example, m/z 850.7857 in Figure 1A was assigned as the ammonium ion adduct of a TG (50:1) lipid (calculated m/z 850.7858), with the experimental and calculated m/z values differing by only 0.0001 Da (0.08 ppm).…”
Section: Resultsmentioning
confidence: 99%
“…Mass spectra were acquired in positive and negative ionization modes using the FT analyzer operating at 100,000 resolving power. Assignment of the molecular lipid compositions 25 of selected ions from the underivatized sample was achieved using Higher-Energy Collision Induced Dissociation (HCD-MS/MS) and/or ion trap CID-MS/MS and -MS n . Further details are available in the attached Supplemental Information.…”
Section: Methodsmentioning
confidence: 99%
“…407 (17), 2015. Recently edited books and monographs on the areas of lipid analysis and lipidomics [6, 33, 34] should be the useful resources.…”
Section: Recommended Lipidomics Resourcesmentioning
confidence: 99%
“…4(c) and 4(d)) and, thus, Eqns. (5) and (6) can be used for a rough estimation of parameters of calibration curves for polyunsaturated PC as well.…”
Section: Response Dependences On Fatty Acyl Length and Db Numbermentioning
confidence: 99%
“…[2] These functions of PC are associated with several diseases connected with deviations from the normal lipid expression. [3][4][5][6] Quantitative lipidomic analysis can be used for disease biomarker discoveries. Electrospray ionization mass spectrometry (ESI-MS) is commonly used in lipidomic studies.…”
mentioning
confidence: 99%