2008
DOI: 10.1016/j.chroma.2007.11.011
|View full text |Cite
|
Sign up to set email alerts
|

Liquid chromatographic determination of enrofloxacin in nasal secretions and plasma of healthy pigs using restricted access material for on-line sample clean-up

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2009
2009
2024
2024

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 32 publications
(11 citation statements)
references
References 23 publications
0
11
0
Order By: Relevance
“…The robustness of RAM supports for direct injection of biological fluids has been described in literature, e.g., 200-2000 repeated injections of plasma samples were performed by Schafer et al [252] without a decrease in RAM column extraction performance. Recent applications include, e.g., the determination of enrofloxacin in nasal secretions and in the plasma of pigs [253] as well as the determination of antidepressant drugs in plasma and urine [254]. As a new trend, a completely new sorbent combining restricted access material together with molecularly imprinted polymer (RAM-MIP, Fig.…”
Section: Restricted Access Materials (Ram)mentioning
confidence: 99%
“…The robustness of RAM supports for direct injection of biological fluids has been described in literature, e.g., 200-2000 repeated injections of plasma samples were performed by Schafer et al [252] without a decrease in RAM column extraction performance. Recent applications include, e.g., the determination of enrofloxacin in nasal secretions and in the plasma of pigs [253] as well as the determination of antidepressant drugs in plasma and urine [254]. As a new trend, a completely new sorbent combining restricted access material together with molecularly imprinted polymer (RAM-MIP, Fig.…”
Section: Restricted Access Materials (Ram)mentioning
confidence: 99%
“…Since then, several publications (over 70) have used this new approach in analytical validation, 18 publications are devoted to discussions on the concept of this approach, 31 have applied the approach in the validation of bioanalytical methods, 10 for pharmaceutical methods, 7 for the analysis of plant materials, 6 to transfer of analytical methods from one laboratory to another, and 6 publications for other applications (food processing, environmental control, etc.) …”
Section: Introductionmentioning
confidence: 99%
“…Several methods had been proposed for determination of ENR and CIP in biological samples [2][3][4][5]. Generally, a preliminary extraction step by liquid-liquid extraction (LLE) or solid-phase extraction (SPE) was employed to make the sample clean enough for further analysis.…”
Section: Introductionmentioning
confidence: 99%