1990
DOI: 10.1093/chromsci/28.9.482
|View full text |Cite
|
Sign up to set email alerts
|

Liquid Chromatographic Properties and Aqueous Solution Stability of N-Hydroxy-3,4-methylenedioxyamphetamine

Abstract: The reversed-phase liquid chromatographic properties of N-hydroxy-3,4-methylenedioxyamphetamine (NOHMDA) were determined on a C8 stationary phase specifically prepared for the separation of basic compounds. NOHMDA and several N-alkyl MDA derivatives displayed excellent peak shape on this stationary phase without the need for competing bases such as triethylamine. The k' values for NOHMDA varied with mobile phase pH in the range of 2.5 to 6.0, but the retention of the primary amine, MDA, and N-alkyl MDAs remain… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
5
0

Year Published

1994
1994
2010
2010

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(9 citation statements)
references
References 0 publications
4
5
0
Order By: Relevance
“…Especially, at pH 10, N-OH-MDMA was rapidly degraded with a half-life of less than 1 h. In contrast, N-OH-MDMA was stable at least for 24 h at pH 2. This pH-dependent stability is similar to that of N-OH-MDA reported previously [4].…”
Section: Degradation Rates Of N-oh-mdma In Aqueous Solutionsupporting
confidence: 90%
See 3 more Smart Citations
“…Especially, at pH 10, N-OH-MDMA was rapidly degraded with a half-life of less than 1 h. In contrast, N-OH-MDMA was stable at least for 24 h at pH 2. This pH-dependent stability is similar to that of N-OH-MDA reported previously [4].…”
Section: Degradation Rates Of N-oh-mdma In Aqueous Solutionsupporting
confidence: 90%
“…The N-OH-MDA peak shape difference between the two columns was explained by the degree of unreacted silanol. This is supported by a previous report on addition of triethylamine, a silanol masking agent, improves the peak shape of N-OH-MDA [4].…”
Section: Chromatographic Separationsupporting
confidence: 84%
See 2 more Smart Citations
“…And the toxicologist is called upon, therefore, to put to work the most powerful analytical techniques to separate by high performance liquid chromatography [8,[16][17][18][19][20][21][22][23][24][25][26][27]29,30], or gas chromatography [8,11,19,21,[23][24][25][26][27][29][30][31][32][33][34] and identify by mass spectrometry [8,11,19,21,[23][24][25][26][27][28][29][30][31][32][33][34], or nuclear magnetic resonance [17,19,32,35] these various "designer amphetamines". In this article, we shall pres...…”
mentioning
confidence: 99%