2019
DOI: 10.1109/lpt.2018.2889753
|View full text |Cite
|
Sign up to set email alerts
|

Liquid Core Fiber Interferometer for Simultaneous Measurement of Refractive Index and Temperature

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
10
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 26 publications
(10 citation statements)
references
References 21 publications
0
10
0
Order By: Relevance
“…This is an alternative strategy with respect to consider as sensible region the cladding or the external coating. As an example, several papers report hollow core fibers filled or partially filled by gas and liquids to be detected [47,48,49]. In [49] the sensor is liquid-filled hollow core fiber spliced between single mode fibers.…”
Section: Coated Pcf Sensorsmentioning
confidence: 99%
“…This is an alternative strategy with respect to consider as sensible region the cladding or the external coating. As an example, several papers report hollow core fibers filled or partially filled by gas and liquids to be detected [47,48,49]. In [49] the sensor is liquid-filled hollow core fiber spliced between single mode fibers.…”
Section: Coated Pcf Sensorsmentioning
confidence: 99%
“…Consequently, extensive research combines various materials with photonic crystal fiber [ 1 , 2 ], hollow-core fiber (HCF) [ 3 , 4 ], twin-core fiber [ 5 ], and D-shaped fiber [ 6 ] for the fabricated FMZIs. The silica-based fibers combined with the other materials, including liquids [ 4 , 5 , 6 , 7 , 8 , 9 , 10 , 11 , 12 ], nanoparticles [ 13 , 14 ], and 2D materials (graphene) [ 15 , 16 , 17 , 18 , 19 ], would generate much higher sensitivity to external parameters than that of the intrinsic silica fibers. Various configurations for the FMZIs have been proposed in the literature and have been demonstrated their effectiveness [ 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8 , 9 , 12 , 13 , 14 , 15 , 16 , 17 , 18 , 19 , 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 ].…”
Section: Introductionmentioning
confidence: 99%
“…The silica-based fibers combined with the other materials, including liquids [ 4 , 5 , 6 , 7 , 8 , 9 , 10 , 11 , 12 ], nanoparticles [ 13 , 14 ], and 2D materials (graphene) [ 15 , 16 , 17 , 18 , 19 ], would generate much higher sensitivity to external parameters than that of the intrinsic silica fibers. Various configurations for the FMZIs have been proposed in the literature and have been demonstrated their effectiveness [ 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8 , 9 , 12 , 13 , 14 , 15 , 16 , 17 , 18 , 19 , 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 ]. Examples include an FMZI with anti-resonance based on an multi-mode fiber (MMF)-HCF-MMF structure for sensing application [ 21 ], tapered fiber-based FMZI for the refractive index (RI) and temperature (T) measurement [ 22 ], core-offset in-line FMZI [ 23 ], an in-line FMZI with thin-core fiber (TCF)-thin fiber-TCF [ 24 ], and SMF-HCF-SMF structures [ 12 , 20 , 28 , <...>…”
Section: Introductionmentioning
confidence: 99%
“…For these cases, it is quite important to systematically relate the changes observed in the reflected spectrum with the physical variables to be measured. To perform the measurements, some authors have proposed to establish linear relationships between the physical variables and either the dip position of some fringes [12] or the intensity or the shift of a resonant dip wavelength [5]. Other authors have proposed to use the Fourier transform to determine the harmonic components of a FPI's reflection spectrum and relate them with a physical variable [10].…”
Section: Introductionmentioning
confidence: 99%
“…Additionally, they showed that the contrast of their spectral fringes was minimum when the refractive index of the exit medium was around 1.45. Another example of a dual sensor is the proposed in [12] which was implemented by splicing an isopropanol infiltrated hollow core fiber between two single-mode fibers. In that work, authors traced a dip of the spectrum to perform the temperature and refractive index measurements for operating dynamic ranges of 25-80°C and 1.333-1.376, respectively.…”
Section: Introductionmentioning
confidence: 99%