2013
DOI: 10.1007/978-3-319-00768-7_36
|View full text |Cite
|
Sign up to set email alerts
|

Long-Term Effects of Cyclic Environmental Conditions on Paintings in Museum Exhibition by Laser Shearography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 3 publications
0
4
0
Order By: Relevance
“…(7), ϕðm; n; tÞ is computed for modulus 2π, which requires further processing to obtain a continuous phase distribution by application of spatiotemporal phase unwrapping algorithms. 2,26 The pointwise evaluation of the correlation coefficients assumes that ϕðm; n; tÞ varies slower in space ðm; nÞ than all of the other parameters in Eqs. (1) and (2) and is sufficiently constant within a spatial kernel 16 (i.e., small spatial neighborhood of measurement points).…”
Section: Phase Sampling Based On 2 þ 1 Frame Local Correlationmentioning
confidence: 99%
See 1 more Smart Citation
“…(7), ϕðm; n; tÞ is computed for modulus 2π, which requires further processing to obtain a continuous phase distribution by application of spatiotemporal phase unwrapping algorithms. 2,26 The pointwise evaluation of the correlation coefficients assumes that ϕðm; n; tÞ varies slower in space ðm; nÞ than all of the other parameters in Eqs. (1) and (2) and is sufficiently constant within a spatial kernel 16 (i.e., small spatial neighborhood of measurement points).…”
Section: Phase Sampling Based On 2 þ 1 Frame Local Correlationmentioning
confidence: 99%
“…3. 17,25,26 Hardware modules are managed by a unified control software with a user interface for setting and customizing acquisition and synchronization parameters. 28 To perform high-speed transient measurements of a TM sample, the user is required to specify the following parameters:…”
Section: Hardware and Software Implementation Of The Acquisitionmentioning
confidence: 99%
“…In some cases, the sensitivity is desired to be adjustable [14,15]. In Michelson interferometers with one of the mirrors tilted [9], the shearing distance can be changed while the angle of the mirror is changed.…”
Section: Comparing Rp With Wpmentioning
confidence: 99%
“…This optical phase sampling method was chosen because of its superior spatial resolution, allowing for a quantification of the phase sampling at each pixel individually. The specific choice of the number of phase shifts and phase step size was defined on the basis of pilot studies of shearographic measurements on oil-on-canvas paintings in our laboratory settings Khaleghi et al, 2014) as well as literature (Kalms and Jueptner, 2005;Morawitz et al, 2013). Further work might be needed to find an optimal phase sampling technique and corresponding acquisition parameters; however, the ones used in this work were deemed sufficient for our preliminary work.…”
Section: Measurements Of Optical Phase Changesmentioning
confidence: 99%