2020
DOI: 10.1667/rr15499.1
|View full text |Cite
|
Sign up to set email alerts
|

Looking Inside a Prototype Compact X-Ray Tube Comprising CNT-Based Cold Cathode and Transmission-Type Anode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
2
2
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 34 publications
0
2
0
Order By: Relevance
“…In most previous studies, the Wdiamond is used as a transmission target. [17][18][19][20][21][22][23] However, it can be used as a reflection target in distributed X-ray source as well. 16 In this paper, we studied the X-ray production of W-diamond thin-film targets via Monte Carlo (MC) simulation, performed finite-element thermal analysis of the target, and predicted the performance of W-diamond thin-film target in both transmission and reflection configurations.The results of this study can be used to guide the design of distributed X-ray sources with thin-film target.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In most previous studies, the Wdiamond is used as a transmission target. [17][18][19][20][21][22][23] However, it can be used as a reflection target in distributed X-ray source as well. 16 In this paper, we studied the X-ray production of W-diamond thin-film targets via Monte Carlo (MC) simulation, performed finite-element thermal analysis of the target, and predicted the performance of W-diamond thin-film target in both transmission and reflection configurations.The results of this study can be used to guide the design of distributed X-ray sources with thin-film target.…”
Section: Introductionmentioning
confidence: 99%
“…Although the radiative and thermal characteristics of thick X‐ray reflection targets have been studied thoroughly, the properties of thin‐film targets are very different and have not been studied thoroughly. In most previous studies, the W‐diamond is used as a transmission target 17–23 . However, it can be used as a reflection target in distributed X‐ray source as well 16 …”
Section: Introductionmentioning
confidence: 99%
“…[47][48][49] Alternative approaches, by placing external forces such as electrostatic and magnetic forces on the E-beam, are considered to achieve the E-beam focusing for higher transmittance. [50][51][52][53] J. S. Han et al developed a curve-shape elliptical focusing lens above the gate, which achieved a high E-beam transmittance of 95.2%, showing new path for the highperformance X-ray tube. 54 J. Zhang et al demonstrated the effectiveness of introducing external magnetic field to enhance the performance of the gate-type cathodes.…”
mentioning
confidence: 99%