2002
DOI: 10.1097/00004728-200205000-00003
|View full text |Cite
|
Sign up to set email alerts
|

Low-Dose Spiral CT: Application to Surface-Rendered Three-Dimensional Imaging of Central Airways

Abstract: Image quality of surface-rendered three-dimensional images of the central airways is preserved using a lower tube current.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0
5

Year Published

2004
2004
2017
2017

Publication Types

Select...
5
4
1

Relationship

0
10

Authors

Journals

citations
Cited by 34 publications
(16 citation statements)
references
References 22 publications
0
11
0
5
Order By: Relevance
“…Furthermore, employing z-axis modulation, which acquires images at a userspecified image noise level with reduced tube current-time product, can further decrease the radiation dose (31). In general, due to the inherently high contrast between the air-filled tracheal lumen and adjacent softtissue attenuation of the mediastinum, milliamperage can be reduced without negatively affecting the diagnostic capability of multidetector CT in evaluating TBM (32)(33)(34)(35).…”
Section: Multidetector Ct Parametersmentioning
confidence: 99%
“…Furthermore, employing z-axis modulation, which acquires images at a userspecified image noise level with reduced tube current-time product, can further decrease the radiation dose (31). In general, due to the inherently high contrast between the air-filled tracheal lumen and adjacent softtissue attenuation of the mediastinum, milliamperage can be reduced without negatively affecting the diagnostic capability of multidetector CT in evaluating TBM (32)(33)(34)(35).…”
Section: Multidetector Ct Parametersmentioning
confidence: 99%
“…In recent years, VB, as a non-invasive, non-contrast used imaging technique has been recommended for detection of foreign bodies in the tracheobronchial tree due to its high diagnostic value (11,12). Absence of aspiration history in 30% of FBA cases, nonobservation of 90% of aspirated foreign bodies on radiography due to nonopaque appearance of organic foreign bodies, lack of abnormal findings on chest radiographs in 16% -34% of cases and probability of rigid bronchoscopy complications resulted in increased utility of VB in patients suspicious of FBA.…”
Section: Discussionmentioning
confidence: 99%
“…Tetkikler ve akciğer grafileri sonrası ıs-rarlı sorgulamalarımızdan sonra hasta 4 ay önce diş protezinin uykuda kaybolduğunu ve sonrasında gelişen nefes darlığında bu durumu doktorlardan sakladığını belirtmiştir. Çin' de yapılmış bir çalışmada, yabancı cisim aspirasyonu tanı-sı konulan erişkin hastalar doktora en çok kronik öksürük(%67) olmak üzere, hemoptizi(%23), ateş (%19), nefes darlığı (%16) şikâyetleri ile başvurmuştur [4]. Yabancı cisimler arasında ilk sı-rayı % 47 ile tavuk ya da balık kemiği alırken diğerleri diş ya da dental materyal (%23), gıda parçası (%16) ve ilaç tabletiydi (%7).…”
Section: Discussionunclassified