Low-frequency component of photoplethysmogram reflects the autonomic control of blood pressure

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
21
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 32 publications
(21 citation statements)
references
References 62 publications
0
21
0
Order By: Relevance
“…The literature suggests the evaluation of baroreflex sensitivity, muscle sympathetic nerve activity, plasma catecholamines, and heart sympathetic imaging [ 56 ]. Besides that, the assessment by means of photoplethysmography could have been a great association to our analyses, for assessing the underlying status of peripheral blood vessels, and whenever possible, it is suggested using additional physiological cardiovascular measurements, increasing accuracy [ 57 59 ]. Additionally, by analysis of the phase coherence between the oscillations in microvascular blood flow and tissue oxygenation, it would be possible to study cardiovascular and microvascular dynamical processes [ 60 ].…”
Section: Discussionmentioning
confidence: 99%
“…The literature suggests the evaluation of baroreflex sensitivity, muscle sympathetic nerve activity, plasma catecholamines, and heart sympathetic imaging [ 56 ]. Besides that, the assessment by means of photoplethysmography could have been a great association to our analyses, for assessing the underlying status of peripheral blood vessels, and whenever possible, it is suggested using additional physiological cardiovascular measurements, increasing accuracy [ 57 59 ]. Additionally, by analysis of the phase coherence between the oscillations in microvascular blood flow and tissue oxygenation, it would be possible to study cardiovascular and microvascular dynamical processes [ 60 ].…”
Section: Discussionmentioning
confidence: 99%
“…With LED light and light intensity detection, the signals following light absorption change as a function of variations in blood volume during heartbeats. This is the principle of PPG [ 20 , 21 ].…”
Section: Methodsmentioning
confidence: 99%
“…PPG and ABP waves have similarities in terms of morphological aspects at least; FFT was used to remove high frequency noise. In lower frequency regions, a segment from 0.15 to 0.4 Hz, which is a consequence of respiratory effect, and another segment from 0.01 to 0.15 Hz vascular resistance, are divided [ 84 ]. Although in numbers there is coherence between the lower frequency region of PPG and BP, the mechanism or rationale behind the coherence is still debated among researchers [ 84 ].…”
Section: Methodsmentioning
confidence: 99%
“…In lower frequency regions, a segment from 0.15 to 0.4 Hz, which is a consequence of respiratory effect, and another segment from 0.01 to 0.15 Hz vascular resistance, are divided [ 84 ]. Although in numbers there is coherence between the lower frequency region of PPG and BP, the mechanism or rationale behind the coherence is still debated among researchers [ 84 ]. Change in respiration rhythm is reflected in the change in stroke volume which in turn affects PPG wave pattern.…”
Section: Methodsmentioning
confidence: 99%