2015
DOI: 10.4025/actascitechnol.v37i3.26452
|View full text |Cite
|
Sign up to set email alerts
|

<b>Efficiency and operating cost of electrocoagulation system applied to the treatment of dairy industry wastewater

Abstract: ABSTRACT. The objective of this study was to apply the technique of electrocoagulation (EC) in the treatment of dairy industry wastewater, using a system of bench. It was used a source of 10 amps and an electrode of iron containing six plates of 14x6 cm. Were made variation of pH (4.5 to 6), intensity of electric current (1 to 2A) and time of electrolysis (30 to 60 min.). The efficiency of the treatment was confirmed by analysis of turbidity, color and COD. The reduction of turbidity was greater than 98%, reac… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
2
3

Year Published

2017
2017
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(15 citation statements)
references
References 12 publications
0
7
2
3
Order By: Relevance
“…Quando analisado o pH das diferentes indústrias de laticínios (Tabela 1), é possível observar sua variação entre 3,3 e 7,5 (RIVAS et al, 2010;CHEN & LIU, 2012;SIRIANUNTAPIBOON et al, 2005;SARKAR et al, 2006;ABREU et al, 2013;GERALDINO et al, 2015;PORWAL et al, 2015). Para esse parâmetro, são vários regulamentos e normativas que determinam limites.…”
Section: Resultados E Discussõesunclassified
See 2 more Smart Citations
“…Quando analisado o pH das diferentes indústrias de laticínios (Tabela 1), é possível observar sua variação entre 3,3 e 7,5 (RIVAS et al, 2010;CHEN & LIU, 2012;SIRIANUNTAPIBOON et al, 2005;SARKAR et al, 2006;ABREU et al, 2013;GERALDINO et al, 2015;PORWAL et al, 2015). Para esse parâmetro, são vários regulamentos e normativas que determinam limites.…”
Section: Resultados E Discussõesunclassified
“…Processos de eletrocoagulação também foram empregados e as taxas de remoção alcançadas foram de 99,98% para a turbidez, 94,90% para a cor, e 96,36% para a DQO. E quando empregado o processo de oxidação fotocatalítica (UV/H 2 O 2 /ZnO), a remoção alcançada foi de 100% para o parâmetro coliformes termotolerantes (GERALDINO et al, 2015).…”
Section: Usos Finaisunclassified
See 1 more Smart Citation
“…On the basis of these results, it is recommended that a second order kinetics model be used to describe the TSS removal from the anaerobically-pretreated palm POME for the applied voltages of 10, 15 and 20 V. The models can be written as Eqs. (10), (11), and (12). Figure 12 shows the graphical presentation of second-order kinetics models of TSS removal.…”
Section: Ec Kinetic Modelmentioning
confidence: 99%
“…In addition, there were some factors in both processes that should be considered such as labor, maintenance, sludge dewatering and disposal as well as fixed costs. The calculations of electrode wear [28], electric energy consumption, and operating cost were calculated by using the following Eq. 5 Table 2 shows the concentrations of COD and heavy metal (Pb and Cr) in the wastewater after 1 h of electrocoagulation process.…”
Section: Chlorophyll Analysismentioning
confidence: 99%