Abstract: The visual performance ofliquid crystal displays (LCDs) has usually been evaluated by visual inspection during the manufacturing process. One ofthe visual problems hardest to recognize are regions oflow-contrast and non-uniform brightness called muras. The accurate and consistent detection ofthe muras is extremely difficult because there are various shapes and sizes ofmuras and the inspection results tend to depend on the operators. We conducted a study on the quantitative evaluation ofmuras based on visual an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2003
2003
2011
2011

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 0 publications
0
5
0
Order By: Relevance
“…There are also several other issues to be solved in the field of optical simulation in LCDs. It was only very recently that the automated measurement of luminance "muras" was possible 12 in spite of its importance. By developing evaluation techniques of this kind, as well as theoretical design methodologies such as the DLDS method, it is necessary to promote optical design automation.…”
Section: Resultsmentioning
confidence: 99%
“…There are also several other issues to be solved in the field of optical simulation in LCDs. It was only very recently that the automated measurement of luminance "muras" was possible 12 in spite of its importance. By developing evaluation techniques of this kind, as well as theoretical design methodologies such as the DLDS method, it is necessary to promote optical design automation.…”
Section: Resultsmentioning
confidence: 99%
“…Experiments were modified based on SEMI and Mori's experiment. 11,12 In the current study, JNDs of the human eyes were measured by the psychophysics method of 2AFC (two alternatives, forced-choice) to prevent a large judging difference among subjects and using QUEST 7 to shorten the experimental time. The visual contrast threshold of each pattern would be obtained, depending on the subject's response to the changed pattern contrast.…”
Section: Experimental Designmentioning
confidence: 99%
“…(10)Depending on whether the subject's judgment was right or wrong, the program prompted an audio feedback: the signal for "correct" was a "ding," and that for "incorrect" was a "kwang." (11)The result of the judgment was recorded by the computer.…”
Section: Experimental Processmentioning
confidence: 99%
“…The FOS quality is usually evaluated by experienced inspectors and inspection system during manufacturing process. Due to disadvantage of sensory analysis, quantitative evaluation algorithm technique is introduced to effectively extract and assess mura that achieves high-quality stabilization and control in manufacturing inspection process [1][2][3]. Ripple of optical film, in fact, is the wrinkling of thin elastic sheet.…”
Section: Introductionmentioning
confidence: 99%