“…However, organic humidity sensors have some disadvantages such as low operating temperature, low long-term stability and swelling. Carbon nitride humidity sensor has higher linearity than other humidity sensors based on inorganic materials which have a high sensitivity at low humidity range and a low sensitivity at high humidity [15,16]. When water molecules adsorb on carbon nitride film, the hydrogen attack in carbon nitride film could easily break the C N and C N bonds and form C H and N H bonds [9].…”
Section: Resultsmentioning
confidence: 99%
“…However, organic humidity sensors have some disadvantages such as low operating temperature, low long-term stability and swelling. Carbon nitride humidity sensor has higher linearity than other humidity sensors based on inorganic materials which have a high sensitivity at low humidity range and a low sensitivity at high humidity [15,16]. When water molecules adsorb on carbon nitride film, the hydrogen attack in carbon nitride film could easily break the C N and C N bonds and form C H and N H bonds [9].…”
Section: Resultsmentioning
confidence: 99%
“…Generally, response time and recovery time are defined as the time taken to reach 90% of the total impedance change [34] . The response time is about 6 s and the recovery time is about 21 s. The recovery time is much longer than response time, indicating that the water vapor adsorption is endothermic process, and it will take a longer time to desorb from the sensor membrane [35] .…”
Section: Humidity Sensing Propertiesmentioning
confidence: 99%
“…With increasing the RH (75%, 85%, and 95%), more and more water molecules are adsorbed, and the leak conduction is appeared [38]. The capacitance C can be represented by using the following expression [39]:…”
Section: Humidity Sensing Properties Of Nbt-bt6 Nanofibersmentioning
confidence: 99%
“…Generally, the time taken by a sensor to reach 90% of the total impedance change is defined as the response time or recovery time [40]. The response time (as the humidity changes from 11% to 95% RH) is about 2 s and the recovery time (as the humidity changes from 95% to 11% RH) is about 50 s. The adsorption and desorption processes of water vapor are corresponding to the exothermic and endothermic processes, and the endothermic speed is slower than exothermic speed [39]. Hence, the recovery time was longer than the response time.…”
Section: Humidity Sensing Properties Of Nbt-bt6 Nanofibersmentioning