2012
DOI: 10.1016/j.neuroimage.2011.12.056
|View full text |Cite
|
Sign up to set email alerts
|

Magnetic resonance imaging of resting OEF and CMRO2 using a generalized calibration model for hypercapnia and hyperoxia

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

18
184
1

Year Published

2015
2015
2020
2020

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 140 publications
(203 citation statements)
references
References 65 publications
18
184
1
Order By: Relevance
“…This MLV implementation then resulted in multiple data points to uniquely estimate the two unknowns, CMRO 2 and x nb , within each block. There is substantial amount of noise propagation from the CBF and QSM input to the CMRO 2 output, which can be further reduced using a global CMRO 2 constraint as the regularization in Equation [4].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…This MLV implementation then resulted in multiple data points to uniquely estimate the two unknowns, CMRO 2 and x nb , within each block. There is substantial amount of noise propagation from the CBF and QSM input to the CMRO 2 output, which can be further reduced using a global CMRO 2 constraint as the regularization in Equation [4].…”
Section: Discussionmentioning
confidence: 99%
“…l (Eq. [4]) was chosen to be 500. In CGM, the CBF decreased by 16.3 6 7.0 mL/100 g/min (P < .01) after the caffeine challenge.…”
Section: Numerical Simulationmentioning
confidence: 99%
“…Several fMRI methods have been developed to recover baseline CMRO 2 . One of these methods is an extension of calibrated fMRI with both hypercapnia and hyperoxia [14][15][16]. This method has recently been refined using a compartmental BOLD model [66].…”
Section: (D) Linking Microscopic To Macroscopic Parametersmentioning
confidence: 99%
“…The gold standard for OEF imaging is positron emission tomography (PET) that involves a sequence of three scans with injection of 15 O or 18 F that is about 46 min and meanwhile the patient is exposed to a radiation dose of 8300MBq (5). PET imaging has several disadvantages that limit its use.…”
Section: Introductionmentioning
confidence: 99%
“…Gauthier and Hoge (2012) (15) and Bulte (2012) (5) where the first group that used these methods. In the following years (2013, 2016), wise et al (16,17) made some improvement to these methods and gained more accurate results for OEF.…”
Section: Introductionmentioning
confidence: 99%