2010
DOI: 10.1097/mao.0b013e3181f7ad5a
|View full text |Cite
|
Sign up to set email alerts
|

Magnetic Resonance Imaging Safety of the Floating Mass Transducer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 12 publications
0
6
0
Order By: Relevance
“…For patients with middle ear implants containing electromagnetic actuators, there is an additional increased risk of migration of the implanted actuator that may possibly damage the recipient's ossicular chain or functioning inner ear. Prior work by Todt et al [12,13] and Jesacher et al [14] has indicated that this was a severe risk for patient's implanted with the previous generation of the MED EL Vibrant Soundbridge 1 implant. The present study has provided more insights on how severe the risk of actuator migration could be for patient's implanted with a Cochlear™Carina 1 fully-implantable AMEI.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…For patients with middle ear implants containing electromagnetic actuators, there is an additional increased risk of migration of the implanted actuator that may possibly damage the recipient's ossicular chain or functioning inner ear. Prior work by Todt et al [12,13] and Jesacher et al [14] has indicated that this was a severe risk for patient's implanted with the previous generation of the MED EL Vibrant Soundbridge 1 implant. The present study has provided more insights on how severe the risk of actuator migration could be for patient's implanted with a Cochlear™Carina 1 fully-implantable AMEI.…”
Section: Discussionmentioning
confidence: 99%
“…In a prior version of this device, several issues have been detected related to the device's electromagnetic actuator [12]. Studies by Todt et al [12,13] indicated that the implanted actuator could move due to magnetically-induced forces, leading to a number of actuator dislocations. Patients have also reported tremendous pain in the middle ear when being scanned with this device, leading to a premature ending of the procedure [12].…”
Section: Introductionmentioning
confidence: 99%
“…Positional changes after MRI could be detected in FMT couplings to the long process of the incus as well as in couplings to the round window. Interestingly, the functional integrity was not significantly influenced . In a retrospective clinical observation, Todt and co‐workers analysed 19 patients with VSB who underwent one or more MRI scans.…”
Section: Discussionmentioning
confidence: 99%
“…Interestingly, the functional integrity was not significantly influenced. 15 In a retrospective clinical observation, Todt and co-workers analysed 19 patients with VSB who underwent one or more MRI scans. Pain in the middle ear, scanner-related impulse noise, pressure at the receiver bed, as well as changes to the transfer function of the FMT were the frequently observed effects.…”
Section: Introductionmentioning
confidence: 99%
“…Sokolowski et al [35] used LDV to measure round window movability, and to assess ossicular chain functioning after malleus stapes assembly reconstruction. Todt et al [36] studied safety of MRI scanning of implantable hearing devices (floating mass transducers) using LDV.…”
Section: Biomedical and Bioengineering Applications Of Ldvmentioning
confidence: 99%