2004
DOI: 10.1016/j.jmmm.2003.12.1285
|View full text |Cite
|
Sign up to set email alerts
|

Magnetoimpedance in amorphous wires and multifunctional applications: from sensors to tunable artificial microwave materials

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
22
0

Year Published

2005
2005
2016
2016

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 50 publications
(22 citation statements)
references
References 32 publications
0
22
0
Order By: Relevance
“…The analysis is concerned with the calculation of the surface impedance tensor, 1,13,16,20,21 which relates the components of the electric and magnetic field at the sample surface. The surface impedance calculation is based on a solution of Maxwell equations for the electric and magnetic fields together with the Landau-Lifshitz equation.…”
Section: 23mentioning
confidence: 99%
See 1 more Smart Citation
“…The analysis is concerned with the calculation of the surface impedance tensor, 1,13,16,20,21 which relates the components of the electric and magnetic field at the sample surface. The surface impedance calculation is based on a solution of Maxwell equations for the electric and magnetic fields together with the Landau-Lifshitz equation.…”
Section: 23mentioning
confidence: 99%
“…The experimental results are interpreted in terms of the field and frequency dependent surface impedance tensor. 1,13,16,20,21 It is assumed that the ribbon consists of an inner amorphous core and two outer crystalline layers. Neglecting a domain structure, the off-diagonal magnetoimpedance is calculated.…”
Section: Introductionmentioning
confidence: 99%
“…In this case, all expressions for the electric and magnetic field remains the same, and the only difference is the change of the boundary condition (11) for the longitudinal magnetic field at the wire surface [24,25]. Moreover, in the framework of the present model the asymmetric impedance response due to the presence of the DC bias current may be calculated similar to the case of the Co-based amorphous wires [24][25][26]28,29]. To take into account the effect of the bias current the corresponding modification in Eq.…”
Section: Resultsmentioning
confidence: 88%
“…All measurements here presented were performed in the frequency range of 0.01-2 MHz, well below the ferromagnetic resonance observed in this kind of samples [32,33].…”
Section: Frequency Dependence Of Magnetoimpedance and Torsion-impedancementioning
confidence: 98%