2008
DOI: 10.1166/jnn.2008.159
|View full text |Cite
|
Sign up to set email alerts
|

Magnetostatic Interactions and Coercivities of Ferromagnetic Soft Nanowires in Uniform Length Arrays

Abstract: First-order reversal curve diagrams have been used to investigate magnetostatic interactions and average coercivity of individual wires in soft ferromagnetic uniform length nanowire arrays. We present a method for identifying these physical parameters on the out-of-plane first-order reversal curve diagrams: the position of the irreversible part on the critical axis is a good approximation to the average value of the nanowire coercivity and the maximum interaction field is equal to the interaction field at satu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

4
60
0
1

Year Published

2010
2010
2021
2021

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 74 publications
(65 citation statements)
references
References 0 publications
4
60
0
1
Order By: Relevance
“…For most NW array systems, the maximum observed in the FORC diagram can be associated to a good approximation with the average value of the NW coercivity (H FORC c ). 28 However, for small diameters (d $ 40 nm) we found a high coercivity distribution along the H c axis. In these cases the maximum value of the FORC diagram cannot be associated with H FORC c as previously reported.…”
Section: A First Order Reversal Curvesmentioning
confidence: 63%
See 3 more Smart Citations
“…For most NW array systems, the maximum observed in the FORC diagram can be associated to a good approximation with the average value of the NW coercivity (H FORC c ). 28 However, for small diameters (d $ 40 nm) we found a high coercivity distribution along the H c axis. In these cases the maximum value of the FORC diagram cannot be associated with H FORC c as previously reported.…”
Section: A First Order Reversal Curvesmentioning
confidence: 63%
“…The FORC method has proved to be an effective way to characterize magnetic interactions and magnetization reversal in nanomagnet arrays. [28][29][30][31]41 To obtain FORCs one first has to saturate the sample applying a large positive magnetic field. Then, we lower H to the so-called reversal field H r (not yet sufficient to saturate the sample in the negative direction), and measure the magnetization M as a function of H, varying H from H r to the positive saturation field value.…”
Section: A First Order Reversal Curvesmentioning
confidence: 99%
See 2 more Smart Citations
“…The lack of clear FORC distribution delimitation prevents us to extract a precise interaction field value, but a good estimate can be taken as half the distance between peaks A and B. 14,15 All composite samples present a qualitatively similar behavior, with interaction fields of 1.1 6 0.2 Oe.…”
mentioning
confidence: 99%