2016
DOI: 10.1002/cce2.38
|View full text |Cite
|
Sign up to set email alerts
|

Managing infected cardiovascular implantable electronic devices

Abstract: The number of cardiac implantable electronic device (CIED) implants is growing; unfortunately, the rate of device infections is also rising, outpacing the increase in device implantation and paralleling the complexity of current CIEDs and CIED recipients, incurring high morbidity and mortality, long hospital stays, and increased financial cost. For either pocket or lead infection, percutaneous complete removal of the infected device and lead system combined with prolonged antibiotic treatment is the standard a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2017
2017
2018
2018

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 66 publications
0
2
0
Order By: Relevance
“…Although reports of longevity have indicated a progressive increase of the life span of ICD devices over the years, from a mean of 19 months in 1980 to 48 months in 2009 to 65 months in 2015, there is still room for improvement, as this is quite an expensive therapy and patient and physician expectations run high for a more satisfactory performance of these devices, a crucial determinant of cost‐efficacy of ICD therapy . Reducing the frequency of generator replacements would also reduce the frequency of important complications, such as device infection, and their consequent costs . Real‐life longevity is definitely sharply shorter compared with the industry‐projected longevity, which has always overestimated ICD device performance …”
Section: Discussionmentioning
confidence: 99%
“…Although reports of longevity have indicated a progressive increase of the life span of ICD devices over the years, from a mean of 19 months in 1980 to 48 months in 2009 to 65 months in 2015, there is still room for improvement, as this is quite an expensive therapy and patient and physician expectations run high for a more satisfactory performance of these devices, a crucial determinant of cost‐efficacy of ICD therapy . Reducing the frequency of generator replacements would also reduce the frequency of important complications, such as device infection, and their consequent costs . Real‐life longevity is definitely sharply shorter compared with the industry‐projected longevity, which has always overestimated ICD device performance …”
Section: Discussionmentioning
confidence: 99%
“…Unfortunately, complications associated with CIEDs have also been increasing ( 3 , 4 , 16 ). Particularly, device infections appear to be rising out of proportion to increasing implant rates ( 17 ). Furthermore, device recipients who develop device infection have increased device-dependent, long-term mortality even after successful treatment of infection ( 18 ).…”
Section: Discussionmentioning
confidence: 99%