2017
DOI: 10.13109/zptm.2017.63.2.189
|View full text |Cite
|
Sign up to set email alerts
|

Manualisierte Psychotherapie zur Optimierung der Immunsuppressiva-Adhärenz bei Patienten nach Nierentransplantation: Ergebnisse einer Machbarkeitsstudie

Abstract: Summary Manualized psychotherapy for the optimization of immunosuppressant adherence following kidney transplantation: Results of a feasibility studyObjectives: Adherence can be defined as the extent to which patients follow the instructions for prescribed treatments. Up to 37 % of renal transplant recipients are classified as nonadherent to immunosuppressant medication. Nonadherence, however, is significantly correlated with transplant rejection and loss. The objective of this manual is to optimize adherence … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
1
0
4

Year Published

2017
2017
2020
2020

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 33 publications
(29 reference statements)
0
1
0
4
Order By: Relevance
“…It is often declared as the best estimate of NA [13,15,21], since it provides insight into the dynamics of both taking and timing adherence over a period of time [8,15]. Although the utilization of EM as a method for monitoring immunosuppressive NA is on the rise and used in a variety of studies [22][23][24][25][26][27], the accuracy of this method is still being debated. Electronic malfunction, incorrect use, negative change in routine, but also an induced intervention effect resulting in improved adherence, are considered potential causes for imprecise EM measures [21,[28][29][30][31].…”
Section: Introductionmentioning
confidence: 99%
“…It is often declared as the best estimate of NA [13,15,21], since it provides insight into the dynamics of both taking and timing adherence over a period of time [8,15]. Although the utilization of EM as a method for monitoring immunosuppressive NA is on the rise and used in a variety of studies [22][23][24][25][26][27], the accuracy of this method is still being debated. Electronic malfunction, incorrect use, negative change in routine, but also an induced intervention effect resulting in improved adherence, are considered potential causes for imprecise EM measures [21,[28][29][30][31].…”
Section: Introductionmentioning
confidence: 99%
“…Die Informationen lassen sich mithilfe eines Lesegeräts auslesen. Bei der Auswertung wird angenommen, dass auf jedes Öffnen auch die Entnahme und die Einnahme des Medikaments folgt [23,24]. Um Abweichungen wie z.…”
Section: Elektronisches Monitoringunclassified
“…Um Abweichungen wie z. B. vorzeitige Entnahmen, um das Medikament dann unterwegs einzunehmen, festzuhalten, werden die Patienten angehalten, begleitend dazu ein Tagebuch zu führen [24]. Mögliche Fehlerquellen sind einmal technische Störungen des Geräts sowie Anwenderfehler aufseiten der Patienten [20,23].…”
Section: Elektronisches Monitoringunclassified
See 2 more Smart Citations