2013
DOI: 10.1016/j.nucengdes.2012.11.012
|View full text |Cite
|
Sign up to set email alerts
|

Manufacturing of representative axial stress corrosion cracks in tube specimens for eddy current testing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 10 publications
0
2
0
Order By: Relevance
“…To validate that the correlation developed to predict the ligament rupture pressure of PTW EDM flaws in straight tubes can be used to predict the ligament rupture pressure of PTW axial ODSCC, five axial ODSCC specimens were fabricated using straight tubes with and without wear marks are discussed further in the "Manufacturing of Representative Axial Stress Corrosion Cracks in Tube Specimens," report by Bahn et al [11]. Eventually, 28 ODSCC specimens were fabricated from tubes; 19 from tubes without wear marks (Table 2) from tubes with wear mark (Table 3).…”
Section: Validation Tests For Specimens With Axial Odsccmentioning
confidence: 99%
“…To validate that the correlation developed to predict the ligament rupture pressure of PTW EDM flaws in straight tubes can be used to predict the ligament rupture pressure of PTW axial ODSCC, five axial ODSCC specimens were fabricated using straight tubes with and without wear marks are discussed further in the "Manufacturing of Representative Axial Stress Corrosion Cracks in Tube Specimens," report by Bahn et al [11]. Eventually, 28 ODSCC specimens were fabricated from tubes; 19 from tubes without wear marks (Table 2) from tubes with wear mark (Table 3).…”
Section: Validation Tests For Specimens With Axial Odsccmentioning
confidence: 99%
“…Periodic inspection using Eddy current technique is commonly employed to detect various forms of tube degradation including SCC. As a result, it is crucial to assess and validate the reliability of the Eddy current technique used for evaluating the structural dependability of components [12].…”
Section: Steam Generator Tubesmentioning
confidence: 99%