2016
DOI: 10.1155/2016/6547318
|View full text |Cite
|
Sign up to set email alerts
|

MCNP-X Monte Carlo Code Application for Mass Attenuation Coefficients of Concrete at Different Energies by Modeling 3 × 3 Inch NaI(Tl) Detector and Comparison with XCOM and Monte Carlo Data

Abstract: Gamma-ray measurements in various research fields require efficient detectors. One of these research fields is mass attenuation coefficients of different materials. Apart from experimental studies, the Monte Carlo (MC) method has become one of the most popular tools in detector studies. An NaI(Tl) detector has been modeled, and, for a validation study of the modeled NaI(Tl) detector, the absolute efficiency of 3 × 3 inch cylindrical NaI(Tl) detector has been calculated by using the general purpose Monte Carlo … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
23
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
10

Relationship

3
7

Authors

Journals

citations
Cited by 94 publications
(23 citation statements)
references
References 20 publications
0
23
0
Order By: Relevance
“…As a first step in the INPUT file, cell cards and surface cards were prepared using elemental mass fractions (wt %) and material densities ( Table 1 ) of ZBV1, ZBV2, ZBV3, and ZBV4 glasses in the 0.015–10 MeV photon-energy range. Next, MAC values obtained from WinXcom [ 49 ] and MCNPX [ 50 , 51 , 52 ] were compared. The overall MAC values were largely stable regarding variations in incident photon energy.…”
Section: Methodsmentioning
confidence: 99%
“…As a first step in the INPUT file, cell cards and surface cards were prepared using elemental mass fractions (wt %) and material densities ( Table 1 ) of ZBV1, ZBV2, ZBV3, and ZBV4 glasses in the 0.015–10 MeV photon-energy range. Next, MAC values obtained from WinXcom [ 49 ] and MCNPX [ 50 , 51 , 52 ] were compared. The overall MAC values were largely stable regarding variations in incident photon energy.…”
Section: Methodsmentioning
confidence: 99%
“…Estımatıon of Absorbed Dose Dıstrıbutıon in Dıfferent Organs durıng the CT Scan: Monte Carlo Study most accurate, reliable, and versatile in accomplishing this task [1][2][3][4][5][6][7][8].…”
Section: Special Article -Therapeutic Radiologymentioning
confidence: 99%
“…(16). Various simulation investigations on medical applications and for other aims by using MCNPX Monte Carlo code are found in literature (17)(18)(19)(20)(21). Apart from the general approaches to medical applications of MCNPX code, MCNPX is also significantly useful and effective tool for mammography investigations (22).…”
Section: Simulation Geometry Setup and Validationmentioning
confidence: 99%