2009
DOI: 10.1080/18811248.2007.9711569
|View full text |Cite
|
Sign up to set email alerts
|

Measurement and Analysis of Reactivity Worth of237Np Sample in Cores of TCA and FCA

Abstract: The reactivity worth of 22.87 grams of 237 Np oxide sample was measured and analyzed in seven uranium cores in the Tank-Type Critical Assembly (TCA) and two uranium cores in the Fast Critical Assembly (FCA) at the Japan Atomic Energy Agency. The TCA cores provided a systematic variation in the neutron spectrum between the thermal and resonance energy regions. The FCA cores, XXI and XXV, provided a hard neutron spectrum of the fast reactor and a soft one of the resonance energy region, respectively. Analyses we… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2011
2011
2018
2018

Publication Types

Select...
4

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 17 publications
0
6
0
Order By: Relevance
“…The sample reactivity worths were corrected for the influence of the difference between H 2 and H ref to fit the function Eq. (1) to the distribution of corrected sample reactivity worths at H ref , through the following repeated procedure that was proposed in the reference: 10) 1) Equation (1) was fitted to the temporary distribution of the sample reactivity worths with no correction, through which the value of Á mx could be evaluated. …”
Section: Experimental Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…The sample reactivity worths were corrected for the influence of the difference between H 2 and H ref to fit the function Eq. (1) to the distribution of corrected sample reactivity worths at H ref , through the following repeated procedure that was proposed in the reference: 10) 1) Equation (1) was fitted to the temporary distribution of the sample reactivity worths with no correction, through which the value of Á mx could be evaluated. …”
Section: Experimental Methodsmentioning
confidence: 99%
“…In the 1.42S core, the K determined in the reference 10) was used for this technique. In the uniform cores, those given in the reference 15) were employed after making a small correction of less than 3% for the difference in reactivity between the set of delayed neutron parameters prepared for each core and the fixed set of those actually used in the reactivity meter when the K was determined.…”
Section: Experimental Methodsmentioning
confidence: 99%
See 3 more Smart Citations