2012
DOI: 10.1097/ico.0b013e31820e42b5
|View full text |Cite
|
Sign up to set email alerts
|

Measurement Area and Repeatability of Semiautomated Assessment of Corneal Endothelium in the Topcon Specular Microscope SP-2000P and IMAGEnet System

Abstract: Repeatability is improved when larger measurement areas are chosen.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 21 publications
0
5
0
Order By: Relevance
“…The Topcon SP2000P has the ability to measure ECD, HEX, and CV. The mechanism of the Topcon SP2000P has already been described in other studies, 23 and the repeatability 27 and validity 28 of the Topcon SP2000P have previously been reported. As for the results of the Topcon SP2000P, the system monitors the entire process automatically and then presents acceptable measurements.…”
Section: Methodsmentioning
confidence: 53%
“…The Topcon SP2000P has the ability to measure ECD, HEX, and CV. The mechanism of the Topcon SP2000P has already been described in other studies, 23 and the repeatability 27 and validity 28 of the Topcon SP2000P have previously been reported. As for the results of the Topcon SP2000P, the system monitors the entire process automatically and then presents acceptable measurements.…”
Section: Methodsmentioning
confidence: 53%
“…), all measurements were performed with the same specular microscope used prior to implantation, and all measurements were performed using the same protocol, cutting out most variation that can be induced by changing surgeons or measurement methods. [25][26][27][28] ENDOTHELIAL CELL DENSITY: We calculated the percentage of total EC loss and the percentage of total EC loss corrected for an annual physiological loss of 0.6% by using the results of the mixed-model linear regression analyses. 22,23 After 6 months, the acute EC loss in the myopic and toric groups was similar to the 0.05% to 4.3% short-term EC loss after 6 months reported in the literature, 1,3,29 with 0.7% and 1.6% of eyes showing a decrease in ECD > _ 25% after uncomplicated surgery, respectively (data on file).…”
Section: Despite the Multitude Of Anterior Chamber Piolsmentioning
confidence: 99%
“…Specular microscopy is used as a selection criteria for cataract surgery in humans to evaluate and quantify corneal endothelial cells . However, in veterinary medicine, specular microscopy has been reported only in the scope of investigative ophthalmology .…”
Section: Introductionmentioning
confidence: 99%