2016
DOI: 10.1109/tpwrs.2015.2477080
|View full text |Cite
|
Sign up to set email alerts
|

Measurement-Based Real-Time Voltage Stability Monitoring for Load Areas

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
61
0
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
3
3
1

Relationship

0
7

Authors

Journals

citations
Cited by 86 publications
(62 citation statements)
references
References 22 publications
0
61
0
1
Order By: Relevance
“…The fictitious loads in conventional Ward equivalent models are constant-current or constant-power loads; therefore, the nodal admittance matrix (or the parameters) of the equivalent model can be determined by performing Gaussian elimination on the nodal admittance matrix of the area load. Paper [11] treats these loads as constant impedances, and the model parameters are determined using measurements collected at the boundary buses. In this paper, the accuracy of the model is improved by formulating ZIP models of the active and reactive loads as follows [30]:…”
Section: Area Load Modeling and Topological Structure Simplification mentioning
confidence: 99%
See 3 more Smart Citations
“…The fictitious loads in conventional Ward equivalent models are constant-current or constant-power loads; therefore, the nodal admittance matrix (or the parameters) of the equivalent model can be determined by performing Gaussian elimination on the nodal admittance matrix of the area load. Paper [11] treats these loads as constant impedances, and the model parameters are determined using measurements collected at the boundary buses. In this paper, the accuracy of the model is improved by formulating ZIP models of the active and reactive loads as follows [30]:…”
Section: Area Load Modeling and Topological Structure Simplification mentioning
confidence: 99%
“…The ERL, FORL and LS algorithms are used to optimize the coefficients of the ZIP load in accordance with the real-time voltage measurements. As is done in [11], the initial values in the current time window are set to the optimal values for the last time window in the LS algorithm. The parameters of the ERL algorithm are set as follows: D i = 10 (i = 1, 2, · · · , N), α = 0.5, β = 0.1 and γ = 0.9.…”
Section: Single Zip Loadmentioning
confidence: 99%
See 2 more Smart Citations
“…Voltage instability has become a challenging issue in power grids since several major blackouts worldwide have been mainly attributed to voltage collapse [1][2][3]. Voltage collapse tends to occur during heavy loading, especially when the generating capacity is insufficient.…”
Section: Introductionmentioning
confidence: 99%