2020 IEEE International Instrumentation and Measurement Technology Conference (I2MTC) 2020
DOI: 10.1109/i2mtc43012.2020.9128713
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of Cardiac Parameters by Motion Artifacts Free Photoplethysmography Signals

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
3
3

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 12 publications
0
5
0
Order By: Relevance
“…Although the acceleration-based adaptive filter could improve the accuracy of HR calculation, such adaptive filters are still dependent on the signal quality of the reference acceleration signal [28]. The previous study [19] had addressed this issue by proposing the bandstop filter based on the 3-axis acceleration reference, the work was mainly proposed to address the motion scenarios with lower intensity. The ANF described in the present study has effectively removed MAs and recovered cleansed PPG signals using a reference signal from the 3-axis accelerometer at different motion intensities.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Although the acceleration-based adaptive filter could improve the accuracy of HR calculation, such adaptive filters are still dependent on the signal quality of the reference acceleration signal [28]. The previous study [19] had addressed this issue by proposing the bandstop filter based on the 3-axis acceleration reference, the work was mainly proposed to address the motion scenarios with lower intensity. The ANF described in the present study has effectively removed MAs and recovered cleansed PPG signals using a reference signal from the 3-axis accelerometer at different motion intensities.…”
Section: Discussionmentioning
confidence: 99%
“…The performance of AF is highly associated with the quality of reference signal, i.e., acceleration signal) as is linearly related to the MAs. Such AF is uneasily applied for a real-time MAs cancellation [19].…”
Section: Introductionmentioning
confidence: 99%
“…The As known, the PPG signals can be affected by any voluntary or involuntary subject motions. The authors previously proposed a robust sensor fusion technique (by using of PPG sensor and accelerometer data) to remove motion artifacts from the recorded PPG signals [19]. In this regard, as future work, the accelerometer output signals measured by the wristband will be used to eliminate the motion artifacts in the recorded PPG signals.…”
Section: Discussionmentioning
confidence: 99%
“…These MAs may be generated by a motion-induced variation in the distance between the optical sensor and skin surface, contact pressure modulation, and by hemodynamic effects [5]. Hence, MA-corrupted PPG signals may significantly reduce the accuracy and stability of physiological monitoring [6]. Several methods have been presented to reduce MAs and extract the desired PPG signal, such as Independent Component Analysis (ICA) [7], Empirical Mode Decomposition (EMD) [8], Fast Fourier Transformation (FFT) [9], and wavelet de-noising approaches [10].…”
Section: Introductionmentioning
confidence: 99%