2018
DOI: 10.1515/cse-2018-0001
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of HDO Products Using GC-TCD: Towards Obtaining Reliable Analytical Data

Abstract: This paper reported the method development and validation of a gas chromatography with thermal conductivity detector (GC-TCD) method for the measurement of the gaseous products of hydrodeoxygenation (HDO). The method validation parameters include selectivity, precision (repeatability and reproducibility), accuracy, linearity, limit of detection (LoD), limit of quantitation (LoQ), and robustness. The results showed that the developed method was able to separate the target components (H2, CO2, CH4 and CO) from t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
13
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 8 publications
(14 citation statements)
references
References 4 publications
1
13
0
Order By: Relevance
“…Based on analytical principle, the intraday precision of the GC-TCD method in this study can be considered acceptable since the %RSD values for every component in one day was found to be lower than 0.67 times of their corresponding CV Horwitz values (Zuas et al 2018). These results were found to be comparable with previous experiment reported for the measurement of H 2 , CO, CH 4 , or CO 2 (Li & Guan 2009).…”
Section: B Intraday Precision and Interday Precisionsupporting
confidence: 87%
See 4 more Smart Citations
“…Based on analytical principle, the intraday precision of the GC-TCD method in this study can be considered acceptable since the %RSD values for every component in one day was found to be lower than 0.67 times of their corresponding CV Horwitz values (Zuas et al 2018). These results were found to be comparable with previous experiment reported for the measurement of H 2 , CO, CH 4 , or CO 2 (Li & Guan 2009).…”
Section: B Intraday Precision and Interday Precisionsupporting
confidence: 87%
“…Based on ISO/IEC 17025 requirements, all method validation parameters were assessed under an optimized GC-TCD condition by adopting a procedure in previous validation study, consisting of identity confi rmation, intraday precision and interday precision, accuracy, linearity, limit of detection (LoD), limit of quantifi cation (LoQ), and roughness (Zuas et al 2018). The validated method was then applied in the measurement of three syn-gas samples.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations