Measurement of Infrared Spectral Directional Hemispherical Reflectance and Emissivity at BNM-LNE

Abstract: An infrared reflectometer has been designed by BNM-LNE (Bureau National de Métrologie-Laboratoire National d'Essais) to measure the spectral directional hemispherical reflectance of solid materials at ambient temperature. For opaque materials, the spectral directional emissivity can be calculated from the measured reflectance. The reflectance can be measured from 0.8 to 14 µm in five directions with an angle of 12 • , 24 • , 36 • , 48 • , and 60 • with respect to the normal to the surface of the sample. The op… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
1
2

Year Published

2008
2008
2018
2018

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 30 publications
(14 citation statements)
references
References 0 publications
0
11
1
2
Order By: Relevance
“…After a few steps, both iterations converge. This static method is realized in different setups, as reported in the literature [7][8][9][10].…”
Section: Conventional Methods To Measure the Spectral Emissivitymentioning
confidence: 99%
See 1 more Smart Citation
“…After a few steps, both iterations converge. This static method is realized in different setups, as reported in the literature [7][8][9][10].…”
Section: Conventional Methods To Measure the Spectral Emissivitymentioning
confidence: 99%
“…Several methods have been proposed and applied to measure the emissivity, mostly based on a static measurement principle [5][6][7][8][9][10][11]. These techniques comprise a reference radiation source with a known emissivity and known temperature, which is usually a blackbody with an emissivity close to unity.…”
Section: Introductionmentioning
confidence: 99%
“…The normal spectral emissivities of two samples, made of the same metals as the cavity and the diaphragm and oxidized by heating in air, were measured using the emissometer described in [14]. The quasi-normal spectral emissivities of the surfaces of a heat flux meter were measured using the reflectometer described in [15]. The total hemispherical emissivities of the surfaces were calculated using the results of normal or quasi-normal spectral emissivity measurements.…”
Section: Calculation Of the Irradiancementioning
confidence: 99%
“…The copper alloy cavity was coated with a specific black paint to ensure a high emissivity in the 3-15 µm spectral range. The spectral emissivity of this paint was measured at LNE [5].…”
Section: Short-term Stabilitymentioning