2020
DOI: 10.3390/electronics9030450
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of Magnetic Field Properties of a 3.0 T/m Air-Core HTS Quadrupole Magnet and Optimal Shape Design to Increase the Critical Current Reduced by the Incident Magnetic Field

Abstract: Air-core high-temperature superconducting quadrupole magnets (AHQMs) differ from conventional iron-core quadrupole magnets, in that their iron cores are removed, and instead high-temperature superconductors (HTSs) are applied. The high operating temperature and high thermal stability of HTS magnets can improve their thermodynamic cooling efficiency. Thus, HTS magnets are more suitable than low temperature superconducting magnets for withstanding radiation and high heat loads in the hot cells of accelerators. A… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(1 citation statement)
references
References 24 publications
0
1
0
Order By: Relevance
“…Often the underlying values are taken from real wire data measured at the desired operating temperature (T) and possibly for fields applied both parallel and perpendicular to the wire surface to account in a minimalistic (and unrealistic) manner for the true I c anisotropy of the wire through an elliptical approximation [2,3]. Far less common is the use of actual angle-dependent critical current data I c (T,B,θ), either approximately functionalised [4] or employed directly [5][6][7] due to issues of both the availability and reliability of such data and the perceived * Author to whom any correspondence should be addressed. difficulty or computational overhead of modelling using real data tables in place of functional approximations.…”
Section: Introductionmentioning
confidence: 99%
“…Often the underlying values are taken from real wire data measured at the desired operating temperature (T) and possibly for fields applied both parallel and perpendicular to the wire surface to account in a minimalistic (and unrealistic) manner for the true I c anisotropy of the wire through an elliptical approximation [2,3]. Far less common is the use of actual angle-dependent critical current data I c (T,B,θ), either approximately functionalised [4] or employed directly [5][6][7] due to issues of both the availability and reliability of such data and the perceived * Author to whom any correspondence should be addressed. difficulty or computational overhead of modelling using real data tables in place of functional approximations.…”
Section: Introductionmentioning
confidence: 99%